813483
41
Zoom out
Zoom in
Previous page
1/52
Next page
41
Pilot Burner Bracket
To remove the Pilot Burner Bracket:
6.9 First remove the electrode, pilot pipe and thermocouple
as described in the following sections.
6.10 Remove the 2 screws securing the bracket. The pilot burner
bracket can now be removed.
6.11 Replace in reverse order.
Electrode
6.12 Pull the ignition lead off the electrode and undo the retaining
nut, see Diagram 27.
6.13 Replace with a new electrode. Do not over-tighten the nut;
this could break the component.
6.14 Replace the ignition lead by pushing the spade connector
onto the terminal (electrode).
Pilot Injector
6.15 Undo the pilot pipe from the gas valve and from the
underside of the pilot burner, see Diagram 27.
6.16 Remove the pipe and the injector drops out from the burner.
Thermocouple
6.17 Disconnect the thermocouple from the gas valve.
6.18 Undo the thermocouple nut in the back of the pilot bracket
half a turn. This releases the thermocouple.
6.19 When replacing with a new thermocouple, take care to bend
the new component to the same shape as the thermocouple
just removed.
6.20 To refit the thermocouple into the pilot bracket, ensure it is
pushed fully into the hole. There is a stop on the
thermocouple to set the height.
6.21 Lock the retaining nut just enough to grip the thermocouple.
6.22 Connect the thermocouple to the valve taking care not to
over-tighten.
7. Ignition Lead
7.1 Follow the Pilot Unit instruction to access the back of the
pilot assembly.
7.2 Disconnect the ignition lead from the electrode.
7.3 Remove the front cover from the control valve by removing
the retaining screw, see Diagram 28 and gently levering
clear with flat bladed screwdriver, see Diagram 29.
NOTE: There is a small cylindrical metal spacer inside
the cover, this must be kept and replaced on the fixing
screw on re-assembly
28
29
7.4 Disconnect the other end of the ignition lead from the valve
body noting the route of the ignition lead.
7.5 Replace with a new ignition lead following the same route
as the old one.
Replace the valve cover and the pilot assembly.
7.6 Check operation of the new ignition lead.
8. Piezo
8.1 The piezo assembly used on this appliance is not
serviceable and is not likely to fail.
8.2 If a new piezo is required it will be necessary to change the
valve, see Section 9.
Servicing Instructions - Replacing Parts
41


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gazco Huntingdon 20-30-40 - Balanced Flue at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gazco Huntingdon 20-30-40 - Balanced Flue in the language / languages: English as an attachment in your email.

The manual is 3.33 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info