1. FLUE AND CHIMNEY REQUIREMENTS
1.1 The chimney or flue system must comply with the rules in
force, and must be a minimum of 127mm in diameter. (5").
1.2 The minimum effective height of the flue or chimney must
be 3 metres (10ft). Any horizontal flue run from the rear
outlet should not exceed 100mm from the back of the
appliance.
1.3 The chimney or flue must be free from any obstruction. Any
damper plates should be removed or secured in the fully
open position, and no restrictor plates should be fitted.
1.4 The chimney should be swept prior to the installation of the
appliance. However, where it can be seen that the chimney
is clean and unobstructed throughout its entire length, it
need not be swept.
NOTE: If it is intended to fit the stove into a existing brick
built chimney a 5" (127mm) liner must be used. Larger lined
flues may work, but in some instances could cause cold
start flue problems resulting in nuisance shutdown. Lined
flues above 7" (175mm) are not recommended.
Due to recent changes to European chimney standards, new
flue’s and chimney’s are now described by their
temperature, pressure and resistance to corrosion,
condensation and fire. To assist in identifying the correct
flue system, the minimum flue specification is shown in the
technical specification on page 8 of this book. Existing
chimney’s are not covered by this system.
2. VENTILATION
2.1 Consult the rules in force.
Note: This appliance does not normally require any
additional ventilation when installed in G.B.
3. INSTALLATION OF THE GAS SUPPY
3.1 Before installation, ensure that the local distribution
conditions (identification of the type of gas and pressure)
and the adjustment of the appliance are compatible.
3.2 Ensure that the gas supply is capable of delivering the
required amount of gas, and is in accordance with the rules
in force.
3.3 Soft copper tubing and soft soldered joints can be used but
must not be closer than 50mm to the base of the tray.
3.4 A means of isolating the gas supply to the appliance must
be provided independent of any appliance control.
3.5 All supply gas pipes must be purged of any debris that may
have entered, prior to connection to the appliance.
4. APPLIANCE LOCATION
4.1 This fire must stand on a non-combustible hearth that is at
least 12mm thick and projects 50mm minimum from the
base of the fire in all directions.
4.2 Do not install in a room that contains a bath or shower.
MINIMUM CLEARANCE
4.3 The fire is not suitable for installation against a combustible
wall. All combustible materials must be removed from
behind the fire.
4.4 Ensure you comply with all minimum clearance
measurements, whether or not to combustible materials.
See diagram 2 & 2A.
The above dimensions provide adequate clearance at the
side and rear of the fire so that controls can be reached.
9
INSTALLATION INSTRUCTIONS
SITE REQUIREMENTS
1
A = 562mm
B = 431mm
C = 12mm
AR1468
AR1469
50
2
3
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gazco F40 Avanti Conventional Coal at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gazco F40 Avanti Conventional Coal in the language / languages: English as an attachment in your email.

The manual is 3.44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info