813395
29
Zoom out
Zoom in
Previous page
1/32
Next page
29
8. MAIN INJECTOR
8.1 With the firebox clear of the carcass it is possible to access
to the control valve located on the bottom of the firebox
and undo the ø 8mm injector feed pipe fitting.
8.2 Working from inside the firebox remove the lock nut from
the injector (see Diagram 11).
AR0618
11
8.3 Extract the injector with the feed pipe from beneath the
stove.
8.4 Holding the injector with a spanner:
8.5 Undo the feed pipe. Note the orientation of the Injector.
8.6 Re-assemble in reverse order.
8.7 Turn on the gas supply and check for leaks.
9. PRIMARY AERATION PLATE
NOTE: Not all models have aeration plates. Please refer
to the Technical Specification.
9.1 To replace the primary aeration plate turn off the gas supply
at the isolation device.
9.2 Remove the burner, as described in Installation Instructions,
Replacing Parts, Section 2.
9.3 Detach the aeration plate from the venturi
(see Diagram 12).
SERVICING INSTRUCTIONS
REPLACING PARTS
AR1694
12
9.4 Reassemble in reverse order.
NOTE: Even if no aeration plate is required, the small
screw must be replaced.
10. CHANGING BETWEEN GAS TYPES
In order to change between gas types you must change the
following items:
- Pilot Injector
- Control Valve **
- Main Injector
- Main Burner
- Aeration Plate
- Data Badge
**NOTE: THE CONTROL VALVE IS FACTORY-SET FOR
THE CORRECT GAS TYPE AND MODEL. A NEW UNIT
WILL NEED TO BE ORDERED WHEN CHANGING
BETWEEN GAS TYPES.
29


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gazco F40 Avanti Balanced Log at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gazco F40 Avanti Balanced Log in the language / languages: English as an attachment in your email.

The manual is 3.87 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info