813472
18
Zoom out
Zoom in
Previous page
1/32
Next page
18
Installation Instructions
3.23 Feed the flue through the wall, making sure it runs smoothly.
On the inside wall:
3.24 Engage the flue in the inner and outer spigots.
3.25 Make sure rubber seals on the spigots are not damaged.
From outside:
3.26 Insert 4 screws in the flanges of the flue terminal.
3.27 Check sealant has formed a water-tight joint to the wall.
3.28 Finally secure the flue to the spigot by drilling a 3.5mm hole
through the larger hole in the spigot and insert the stainless
steel screw provided, see Diagram 4 C.
3.29 Any terminal less than 2m above any access (level ground,
balcony or flat roof with access) must be fitted with the
guard supplied, see Diagram 5.
5
3B Top Exit - Up & Out
3.30 There are two types of top exit flue terminals: vertical and
horizontal (see Site Requirements, Diagram 3, for minimum
and maximum flue lengths).
Decorative Cover
3.31 There is an optional decorative collar, Part No: 8548, to
cover the gap between the top plate and flue.
THIS MUST BE POSITIONED BEFORE INSTALLING THE
FLUE. WHEN INSTALLING A TOP EXIT FLUE, REFER TO
INSTALLATION INSTRUCTIONS, TECHNICAL
SPECIFICATION (PAGE 10) FOR THE APPROPRIATE
SIZE RESTRICTOR.
Restrictors for flues with both Vertical and Horizontal
Sections
Vertical Flue Height Horizontal Length Restrictor Size
500mm - 1490mm 250mm - 1000mm No restrictor
1500mm - 3000mm 250mm - 5000mm Ø 75mm
Reversing Spigots
3.32 The appliance is factory set for rear exit. For top exit reverse
the spigots and blanking plates, see Diagram 6.
Take care not to drop or damage the gaskets. If a restrictor
is required fit this between the small outlet spigot and the air
duct, see Diagram 6. The large outer spigot must be fitted
with the flue fixing hole facing forward.
3.33 REMEMBER TO FIT THE OPTIONAL DECORATIVE
COLLAR IF REQUIRED.
6
3.34 If the horizontal terminal is used assemble the required
amount of vertical flue including the 90° elbow onto the
appliance.
3.35 Drill through the fixing hole in the spigot using a 3.5mm drill
and secure with the screw provided.
Do not forget the optional decorative collar if you have
purchased one.
Wall Plate
3.36 A wall plate is supplied to secure the flue to the inside wall.
Bend the tab to 90° and loosely place on the elbow.
7
3.37 To determine the height of the hole for the horizontal flue,
measure from the hearth to the centre of the elbow,
see Diagram 7.
TAKE CARE WHEN MARKING OUT FOR THE FLUE. IT IS
DIFFICULT TO MOVE AFTER INSTALLATION.
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gazco Clarendon - Conventional Flue at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gazco Clarendon - Conventional Flue in the language / languages: English as an attachment in your email.

The manual is 2.41 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info