714654
109
Zoom out
Zoom in
Previous page
1/120
Next page
EN
109
Problem Reason The Solution
The kettle does not shut
off automatically, when
the water is boiling.
The kettle is not closed
correctly.
Due to high energy loss via excessive evaporation of
water, the temperature control will only work correctly, if
the kettle is closed correctly. For operation, always cover
the kettle by the appropriate lid set or filter system (see:
‘Operation / Preparing the Appliance for Operation’).
Excessive amounts of lime
influence the temperature
control.
Descale the kettle in time (see: ‘Care and Cleaning /
Descaling the Kettle’). Excessive deposits of lime could
damage the kettle.
You are using the appli-
ance at high altitude.
At high altitude (e.g. on high mountains), the ambient
pressure is reduced, leading to a somewhat lower boiling
temperature. Therefore, the temperature for automatic
shut off (100°C) may not be approachable. Switch off
the kettle manually (see: ‘Cancelling Operation’). Set a
lower temperature, before starting a program.
The temperature probe is
damaged.
The temperature probe sticks out of the heating plate
approx. 1cm. Take care during cleaning to avoid damage.
Contact your vendor for examination and repair.
The AUTO STEEP button
flashes during operation or
“E4” is displayed.
The cantilever is blocked. See below: ‘Error Messages’.
The pusher of the filter
system is blocked.
See below: ‘Error Messages’.
An internal error occurred. Unplug the appliance and wait at least 30 minutes. Then
try again. If the problem persists, contact your vendor.
The power base and/
or base of the kettle get
unexpectedly hot during
operation.
Immediately unplug the
appliance.
The power cord has been
wound partly around the
cable storage during ope-
ration.
Leave the appliance cool down. Always unwind the power
cord completely, before operation to avoid overheating.
Check the power cord for any damage (e.g. discoloura-
tion, damage of the insulating sleeve, or deformation).
Do not operate the appliance again, with the power cord
damaged!
109


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gastroback 42440 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gastroback 42440 in the language / languages: English, German as an attachment in your email.

The manual is 0,62 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info