583719
22
Zoom out
Zoom in
Previous page
1/23
Next page
Discharge the air procedure
13
3
Connect assembly pipe to the appropriate valve on the indoor
unit and outdoor unit and tighten the flare nut(as fig.1).
1.The number of bent position of the pipe in the indoor unit should not exceed 10.
2.The number of bent position of the pipe in the indoor unit and the outdoor unit should not
exceed 15.
3. The radius of bent position should more than 10cm.
PIPE
DIAMETER
OF
PIPE
TORQUE(N m)
Liquid pipe 6.35mm ( 1/4 ) 13.7---17.6
9.52mm ( 3/8 ) 34.3---41.2 Gas pipe
Gas pipe 12.7mm ( 1/2 ) 49.0---56.4
NOTICE
Connect charging hose(low pressure) of manifold
gauge to the service port of gas shut-off valve.
Screw down the nut of connecting pipr with wrench(the torque as
follow diagram )
(Fig.1)
gas shut-off
valve
liquid shut-off valve
Service port
gas conne-
cting pipe
liquid connecting pipe
Valve nuts
Service port cap
Allen wrench
(Fig.2)
Open the valve of the low pressure and close
high pressure valve of manifold gauge.
Purge the air from the system using the vacuum
pump until its pressure(low pressure side) is below 12Pa.
Close the low pressure valve and remove the charging
hose from service port .
Use Allen wretch to turn the valve cork of liquid side
for 90 in counter-clockwise, and close it after 10 seconds.
Use soapy water to check for gas leakage especially
fromservice port and flare.
Mount the valve nuts and service port cap to shut-off
valve and service port .
NOTICE
Do not let air leakage into the system during discharge
air procedure.
Vacuum
pump
Service port
(Fig.3)
Manifold gauge
Low pressure
valve
High pressure
valve
Pressure meter
Charging line
2121
Fully open gas shut-off valve and liquid shut-off valve.
22


Need help? Post your question in this forum.

Forumrules
1

Forum

galanz-aus-12cr53ca2

Reset search

  • Hi the vent of my aircon is opening only when switching on main switch
    Then automatically closes.how to use my remote to make the vent open Submitted on 29-11-2022 at 19:50

    Reply Report abuse
  • What BTU Rating is this the aus-12cr53ca2 Air Conditioner Submitted on 2-8-2019 at 07:00

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Galanz AUS-12CR53CA2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Galanz AUS-12CR53CA2 in the language / languages: English as an attachment in your email.

The manual is 2,01 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info