Burr
Oblique
2020
INSTALLATION
Seal of wall hole and fasten of pipe
Use putty to seal the
wall hole.
Use clamp ( pipe fa-
stener ) to secure
the pipe at specified
position.
indoor unit
clamp
screw
get rid of unwanted part
airproof with putty
clip the connecting pipe with clamp
Connecting
cable
OUTDOOR UNIT
Outdoor unit terminal
Connecting
cable
Heat pump type
Cool only type
Indoor unit terminal
Outdoor unit terminal
Connecting
joint
Blue
Blue
White
White
Red
Yellow
Yellow/Green
Yellow/Green
Connect diagram
WARNING
3
2
N
3
2N
4
R1
R2
2
N
2
N
4
Special cable must be used to connect indoor unit and outdoor
unit. It should be ensured that the terminals are not influenced by
external force. Poor connect may cause fire.
The electric box cover must be mounted and secured in position,
otherwise fire or electrical shock may occur because of dust or
moisture.
The connecting cables must be clipped together.
17
7
Wiring
11
1
Flaring the pipe end
12
2
Cut the pipe using a pipe cutter.
Raughness
Remove burrs at the tip of the pipe cut.
Reamer
Burr
Insert a flare nut into the pipe and modify flare.
Outer diameter(mm)
AUS-09C(H)R53CA(G)2 can be connected only to a supplyed with
system impedance no more than 0.376 ,and AUS-12C(H)R53CA(G)2
no more than 0.213 . In case necessary, please consult your supply
authority for system impedance information.
21


Need help? Post your question in this forum.

Forumrules
1

Forum

galanz-aus-12cr53ca2

Reset search

  • Hi the vent of my aircon is opening only when switching on main switch
    Then automatically closes.how to use my remote to make the vent open Submitted on 29-11-2022 at 19:50

    Reply Report abuse
  • What BTU Rating is this the aus-12cr53ca2 Air Conditioner Submitted on 2-8-2019 at 07:00

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Galanz AUS-12CR53CA2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Galanz AUS-12CR53CA2 in the language / languages: English as an attachment in your email.

The manual is 2,01 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info