6.2 PRESSURE SWITCH ADJUSTMENT
The pressure switch shown in the figure acts to keep the
boiler pressure constant by engaging or de-activating the electrical
heating resistance.
This pressure switch is already calibrated to 1.1-1.3 bar during the
initial machine testing stage, but should a different working pressure
be required, it is possible to vary the operational field of the pressure
switch using the regulation screw (U); pressure reduction results in
a reduction in temperature, whilst increasing the pressure will also
increase the water temperature.
The regulation direction is shown in the figure and on the pressure
switch itself.
The pressure varies by 0.1 atm for every complete screw turn,
Warning: Disconnect the electricity supply before
undertaking this operation.
6.3 PUMP PRESSURE CALIBRATION
Insert the filter holder into the unit filled with regularly ground, dosed
and pressed coffee.
Switch on the unit switch (E90) (17) or the unit control keyboard
(D90) (16) and read the pressure on the pump pressure gauge
(11).
NB: The correct pressure is of 8-9 atm.
Should the pressure indicated on the pressure gauge be incorrect,
turn it clockwise to increase the pump pressure and anti-clockwise
to reduce the pressure.
Once adjustment is complete check pump calibration by delivering
one or more coffees.
Z= Pump pressure adjustment screw.
Warning !!
When the machine is new the filter-holder sump may not be
aligned (perpendicular to the machine itself) as shown in
the figure at the side, however this does not effect the efficient
function of the same.
After a short period of use the sump will gradually settle into
a correct position.
A = Position of closed filter-holder with new machine.
B = Position of closed filter holder with machine after a short
period of use.
6.4 FILTERS FOR COFFEE MACHINE
Depending on the quantity of coffee ground, the appropriate filter
must be as shown below to avoid that, once the coffee has dripped
out, the leftover powder remains attached to the nozzle.
IMPORTANT: N°2 under-tile packings with are thinner
(8.1mm ) than that fitted as standard are included. These
packings may be used in the event of difficulty with insertion
of the filter holder.
NF08/002/B
1 coffee cup of 5,5 gr. ÷ 6,5 gr.
pod for 1 coffee
barley pod for 1 dose
NF08/004/B
1 coffee cup of 6 gr. ÷ 7 gr.
NF08/005/B
2 coffee cups of 12 gr. ÷ 14 gr.
NF08/009/B
Double pod for 2 coffees
The filter may be recognised
by the letter “C” printed
inside
Fig.6.03
Fig.6.05
Fig.6.04
U
Z
20 mm
24,5 mm
24,5 mm
21 mm
Fig.6.06
A
30


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gaggia E90 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gaggia E90 in the language / languages: English as an attachment in your email.

The manual is 4,35 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info