9
Remove the lter and wash it thoroughly with hot
water.
- Remove the adapter (if tted), and wash it thoroughly
with hot water.
- Wash the internal part of the pressurized lter holder.
Do not dry the machine and/or its parts using a microwave
and/or standard oven.
Note: do not wash the pressurized lter holder
in the dishwasher.
12 Descaling
Limescale is a natural part of the water used for machine
operation. It needs to be removed regularly as it may clog the
water and coee circuit of your appliance.
This is an easy procedure for your Gaggia machine. When the
" " light (19) turns on, a descaling cycle is recommended.
When the " " light (19) starts blinking, descaling is
compulsory.
This operation needs to be carried out before
the appliance stops working properly, as in this
case repair is not covered by warranty.
Use the Gaggia descaling product (Fig. B).
Its formula has been designed to ensure
better machine performance and operation for its
whole operating life. If correctly used, it also avoids
alterations in the brewed product. Before starting a
descaling cycle make sure that: THE WATER FILTER (if
used) HAS BEEN REMOVED.
Never drink the descaling solution or any
products dispensed until the cycle has been fully
carried out. Never use vinegar as a descaling solution.
1
13
14
Insert the lter holder (21) into the brew unit (4)
from the bottom. Turn the pressurized lter holder from
left to right until it locks into place. Release the pressurized
lter holder grip. The handle will turn slightly to the left.
This movement guarantees optimum lter holder perfor-
mance.
2
1
Remove and empty the water tank.
3
2
Pour HALF the content of the Gaggia concentrated
descaling solution into the water tank, then ll the tank
with fresh drinking water up to the MAX level.
4
4
Turn on the machine by pressing the ON/OFF button
(11). The " " light (12) turns on.
5
Following the instructions provided in chapter 9 of
this manual, dispense 2 cups of water (about 150ml each)
from the steam wand (Pannarello) and turn the machine
o by pressing the ON/OFF button (11); the " " light (12)
turns o.
5 Let the descaling solution take eect for approx. 15-20
minutes with the machine turned o.
6
Turn on the machine by pressing the ON/OFF " "
button (11).
5
Following the instructions provided in chapter 9 of
this manual, dispense 2 cups of water (about 150ml each)
from the
steam wand (Pannarello).
Turn o the machine
by
pressing the ON/OFF " "
button (11) and leave it o for 3
minutes.
7 Repeat the operations described in step 6 until the water
tank is completely empty.
During this operation the pump is automatically
disengaged and the " " light (20) is blinking:
this is a normal behaviour of the machine. Close the
knob. Wait until the " " light (14) is steady on before
opening the knob again.
8
2
Rinse the water tank with fresh drinking water and ll
it up.
9 Place a container under the lter holder.
10 Turn on the machine by pressing the
" "
ON/OFF button
(11); press the
" "
button (13) and dispense the whole
content of the tank by means of the lter holder. Press the
" "
button (13) again to stop the dispensing process.
11
2
Rell the tank with fresh water.
5
Place a large container (about 1l capacity) under the
steam wand (Pannarello).
Open the water dispensing knob (3) by turning it clock-
wise and dispense the whole content of the water tank by
means of the steam wand (Pannarello).
12
6
After the water dispensing process is complete, close
the water dispensing knob (3) by turning it counter-clock-
wise.
13 Repeat the operations once again from step (8), for a total
of 4 tanks.
14
19
Remove the lter holder from the unit by turning it from
right to left and rinse it with fresh drinking water.
The descaling cycle is now complete.
At the end, press and hold the coee brewing and steam
dispensing buttons for 3 seconds: the descaling light turns o.
2
Rell the tank with fresh water. If necessary, prime the
circuit as described in section 4.6.
4219-450-03711 MANUAL GAG. CAREZZAIT-EN-DE-FR-ES-PT.indd 24 03/12/2018 11:32:21
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gaggia Carezza - RI8523 SIN 042 GB at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gaggia Carezza - RI8523 SIN 042 GB in the language / languages: English, German, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 21,96 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info