781823
21
Zoom out
Zoom in
Previous page
1/50
Next page
Originalbedienungsanleitung FX-SG1-3000 / FX-SG2-3000 de_en_fr_ita_rev2
21
Filling with operating fluids
Before each start, please ensure that the engine has enough oil and enough gasoline in the tank.
Please use only pure 4-stroke engine oil and gasoline with an octane rating of 95 or higher. Do not
use mixtures.
For oil filling, please use the oil filler neck shown in the picture above. To do this, unscrew the cap -
the cap also serves as an oil dipstick.
IMPORTANT NOTICE:
If the dipstick already has a film of oil on it before the initial startup, you must still add oil. The
generator is filled at the factory for test purposes, and after a test run, the oil is pumped out again.
During transport, the engine compartment's residual oil can run back and form an oil film on the
dipstick.
If there is too little oil in the tank, the engine will either not start or will shut down during
operation. That serves to prevent engine damage to your device.
Therefore, check the oil quantity before each start.
Launch
To start, please proceed as follows:
Check oil + add gasoline if necessary.
Ground the generator via the grounding screw (see figure).
The circuit breaker (see picture) must be in the "Off" position.
Set the start switch (see picture) to "On".
When starting cold, push the choke lever (see pictures above) to the left.
Set the fuel tap upwards to the "On" position.
Start the engine utilizing the starter rope.
For a cold start, let the engine run for up to 30sec and only then move the choke lever back to the
right to the "Run" position.
Let the engine warm-up for a few minutes first until you hook up the loads and tap the power. Before
you can let the current flow, you must set the circuit breaker back to the "On" position.
To shut down the generator usually, first disconnect the circuit by setting the circuit breaker to "Off",
then operate the starter switch and set it to "Off" as well, and finally close the fuel cock.
For an EMERGENCY STOP, press the start switch and use this to switch the generator off again.
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fuxtec FX-SG2-3000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fuxtec FX-SG2-3000 in the language / languages: English, German, French, Italian as an attachment in your email.

The manual is 1.62 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info