<Model Menu (Airplane/Glider Functions)>
ŏ Select the function name
and return to the Model
menu by touching the
RTN button or pushing the
HOME/EXIT button.
<SensorTouch™>
RETURN
RUD to ELE
[Corresponding model type]: Airplane, general
This function is used when you want to mix
elevator operation with rudder operation. It is used
to correct undesirable tendencies when rudder is
applied in rolling maneuvers such as, knife edge
ÀLJKW
ŏ Mixing during flight can be turned ON/OFF by
setting a switch. (Always ON at [--] setting)
ŏ Link mixing can be set: Links this mix to other mixes.
ŏ Select [RUD to ELE] at the Model
menu and access the setup screen
shown below by touching the RTN
button.
Scrolling
ŏ Moving cursor
ŏ Selecting mode
ŏ Adjusting value
ŏ To next page
Setting method
Ɣ$FWLYDWHWKHIXQFWLRQ
Move the cursor to the [ACT] item and touch
the RTN button to switch to the data input
mode. Select the ACT mode by scrolling the
touch sensor.
*The display blinks.
Touch the RTN button to activate the
function and return to the cursor mode. (ON
is displayed.)
When selecting a switch, move the cursor to
the [SW] item and touch the RTN button to
call the selection screen. Select the switch
and set its ON direction. (Always ON at "--"
setting)
*For a description of the switch selection method, see the
description at the back of this manual.
ƔSRLQWFXUYHVHWWLQJDLUSODQH
[Curve rate setting]
1. Move the cursor to the curve rate setting
item (left side) you want to adjust and touch
the RTN button to switch to the data input
mode.
Adjust the rate by scrolling the touch sensor.
Adjustment range: -100~100
*When the RTN button is touched for one second, the rate is
reset to the initial value.)
Touch the RTN button to end the adjustment
and return to the cursor mode.
2. Repeat this procedure for each point.
[Moving curve point]
1. Move the cursor to the curve point setting
item you want to adjust and touch the RTN
button to switch to the data input mode.
Adjust the curve point by scrolling the touch
sensor.
Adjustment range: Up to 2.5 in front of the
adjoining point
*When the RTN button is touched for one second, the curve
position is reset to the initial value.)
Touch the RTN button to end the adjustment
and return to the cursor mode.
2. Repeat this procedure for each point.
[Deleting/returning curve point]
Move the cursor to the curve point setting
item you want to delete/return and touch
the RTN button for one second.
Ɣ/LQNPRGHVHWWLQJ
When selecting the link mixing, move the
cursor to the [LINK] item and touch the RTN
button to switch to the data input mode.
Select the ON mode by scrolling the touch
sensor.
*The display blinks.
Touch the RTN button to set the link mode
and return to the cursor mode.
145


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Futaba FX22 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Futaba FX22 in the language / languages: English as an attachment in your email.

The manual is 4,63 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info