29015
9
Zoom out
Zoom in
Previous page
1/12
Next page
The BEC system that makes it easy even for beginners to lighten the ve-
hicle by means of a shared power supply is already well known. The uni-
que
Futaba
ASP
system
is
built
into
the
BF
series
was
completed by
advancing this BEC system one more step and pursuing greater safety.
ASP detects a drop in the voltage and moves the throttle servo automati-
cally to the drive motor off position which is preset at the transmitter
before steering control is lost by a drop in the Nicd battery voltage while
the vehicle is running. It is also the world's first revolutionary system that
allows steering operation with the remaining power.
(Patent pending)
•ASP setting (NEW ATTACK-BFR only)
Before running, set ASP to the controller stop posi-
tion.
If the controller is not set to the stop position, when the
running Nicd battery voltage drops, the throttle servo
may stop at a position other than the stop position and
the vehicle may run wild because the throttle servo can-
not be controlled from the transmitter.
Forward
Stop
Reverse
Since the stop position
differs with the chassis
manufacturer, check it
when connecting the
linkage.
Throttle
servo
Controller
1. Set the transmitter and receiver power switches to on
and check the steering and throttle operations.
2. a) Set the ASP setting switch to the SET side. ASP setting
b) Turn the ASP setting trimmer at the left
side of the
trimmer
switch with a little screwdriver.
c) Since this moves the throttle
servo, set so that it
stops at the stop position of the connected control-
ler.
ASP setting
switch
NORM
SET
ASP
3. Then complete adjustment by setting the ASP setting
switch to the NORM side. (If the switch is not switched
to the NORM side, the throttle servo will not be cont-
rolled by the throttle stick.)
NORM
SET
NORM
When setting ASP
When ASP setting is
complete
Turn
with
a
little
screw-
driver
When the ASP setting
trimmer is turned in the
arrow direction, the
throttle servo turns in
this direction.
Throttle servo
• When the Nicd battery voltage drops, the throttle servo is moved to the preset position and the drive motor is stopped
automatically.
8
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Futaba ATTACK_BFR at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Futaba ATTACK_BFR in the language / languages: English as an attachment in your email.

The manual is 1,78 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info