29053
4
Zoom out
Zoom in
Previous page
1/78
Next page
Airplane Section
AlLERON DIFFERENTIAL (ADF)
This
function
uses
two
separate
aileron
servos
to independently correct yaw tendencies during
rolls. It is possible to adjust each aileron's positive
and
negative
deflection
angles.
When
this
function
is activated, receiver outputs CH1 and CH7 are
used for the two aileron channels. This function
may not be used if Flaperon (FPN) is chosen. If
desired, the amount of down aileron deflection
may be trimmed in flight with a knob or trimmer.
Setting Up Aileron Differential
Activation of command
In the Condition Menu, press the ADF key to get the
AIL DIFF menu shown below. Use the A ( ) key to
activate mode setting, then press the
ACT
or
INH
keys
(
F
and G
)
to
activate or
inhibit
the aileron
dif-
ferential function.
Mode setting
Aileron 1
Left Side rate
Aileron 2
Left Side rate
Aileron 1
Right Side Rate
Aileron 2
Right Side Rate
Trimming volume
Setting
Return to
Condition screen
Mode selection Values in ( ) are the mixing rate, including the trim volume.
Aileron 1 Travel Setting
You now set the amount of servo throw for Aileron 1.
Press the B key to activate travel setting for the Left
direction and set the throw with the numeric keys. The
number keys 0 through 100 input the value directly.
The + and - keys increase or decrease the value by 1.
The +/- key may be used to reverse the throw direc-
tion.
If you are not sure what you are changing, hold the
stick to one side and press different keys — if there is no
effect, move the aileron stick to the other side and con-
tinue. Your setting may vary from -120 to +120%, the
initial value is+100%.
Now set the travel for the Right throw on Aileron 1.
Press the Q key to activate travel setting for the Right
direction and set the throw with the numeric keys as
before.
Aileron 2 Travel Setting
The setting process given above is repeated for Aileron
2. Press the C key to activate travel setting for the Left
direction and set the throw with the numeric keys.
Finally, set the travel for the Right throw on Aileron
2. Press the P key to activate travel setting for the Right
direction and
set
the throw with the numeric keys as
before.
Trim volume setting
You may set up the Aileron Differential function so
that its effect may be changed in flight by moving a trim
control. The trim control adjusts the volume within ±25%
of the set differential rate. This option is not activated at
initial setup.
Call the volume setting screen by pressing the VOL
O key, and select the desired control using the screen
menus (for a description of the volume setting method,
see page 37).
Use the END (N)
key
to
leave
this
menu.
Airplane Section, Page 80
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Futaba 9ZHP_part2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Futaba 9ZHP_part2 in the language / languages: English as an attachment in your email.

The manual is 3,43 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info