SETTING METHOD
CAUTION
Before actually starting the engine, be sure that idle-up switches 1 and 2 are off, and the
throttle is set near engine idle.
To TH-CRV
function
To PI-CRV
IDL1 function
Data input keys
These keys are used
to move between
curve points in the
TH-CRV function.The bottom arrow shows the point
on the five-point curve currently
being set.
Top arrow indicates the current throttle
stick position (2 arrows means it's
between points)
Curve points 1-5
Curve Name
Display
(NORM)
Input 5-point curve values
Move the lower arrow to the
position you want to set with the
CURSOR keys (the curve point is
indicated by the arrow below the
numbers 1-5, and the current
throttle position is above the
numbers). Enter the desired curve
value with the (+)/(-) keys.
• If you're unhappy with what you've
set, you may return to the default
value by pressing the (+) and (-)
keys simultaneously.
Curve Point Value
(Range: 0 - +100%)
Initial curve settings:
POS1 = 0%
POS2 = 25%
POS3 = 50%
POS4 = 75%
POS5 = 100%
The Pitch Curve Normal function is on at startup.
The blinking item on the
setting screen is the
current setting item.
Idle-up 1 Pitch Curve Setting
The PI-CRV IDL1 function will not operate until the OFST1
function is activated. This also activates the IDL1 Throttle &
REVOLU curve menus. You can activate idle-up 1 and idle-up 2
independently.
The curve setting procedure is the same as normal curve
described above.
To PI-CRV NORM
or PI-CRV IDL1 function
To PI-CRV IDL2 or PI-CRV HOLD function
Throttle Hold Pitch Curve Setting
The PI-CRV HOLD function will take data, but will not operate
until the throttle hold (TH-HLD) function is activated.
The curve setting procedure is the same as normal curve
described above.
To PI-CRV IDL2 function
To PI-CRV INVR function
Invert Pitch Curve Setting
The PI-CRV INVR function will take data, but will not operate until
the INVERT function is activated.
The curve setting procedure is the same as normal curve
described above.
To PI-CRV HOLD function
To REVOLU function
94


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Futaba 8UAPS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Futaba 8UAPS in the language / languages: English as an attachment in your email.

The manual is 4,25 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info