522144
14
Zoom out
Zoom in
Previous page
1/52
Next page
2. WIRING
2-4
2.1.3 CAN bus port
Every TZT9/14 has one CAN bus port
(micro style connector). All TZT9/14
MUST be connected to the same CAN
bus backbone. However, the TZT9/14
and DRS (radar sensor) CAN bus ports
cannot be connected together. The TZT9/14 and DRS (radar sensor) use “Ethernet
Bridging” to link the DRS CAN bus and the TZT9/14 CAN bus data. Refer to
paragraph 2.2.1 for more information. Note that the TZT9/14 CAN bus port is not pow-
ered unless external power is applied to the FRUDD-18AFFM-L180 cable of MULTI
port and must be connected to a properly configured CAN bus network.
What is CAN bus?
CAN bus is a communication protocol that shares multiple data and signals through a
single backbone cable. You can simply connect any CAN bus devices onto the back-
bone cable to expand your network onboard. With CAN bus, IDs are assigned to all
the devices in the network, and the status of each sensor in the network can be de-
tected. All the CAN bus devices can be incorporated into the NMEA2000 network. For
detailed information about CAN bus wiring, see “Furuno CAN bus Network Design
Guide” (Type: TIE-00170) on Tech-Net.
DRS radar sensor
In addition to the CAN bus port found on
the TZT9/14, all DRS radar sensors have
one powered CAN bus port (terminal strip
connector). You may directly connect vari-
ous Furuno CAN bus sensors to the DRS
radar sensor without having to run a sepa-
rate CAN bus cable to the mast. The total
number of sensors that can be connected
to the CAN bus DRS port without external
power connection depends on power con-
sumption. The DRS can supply up to 1 amp (20LEN) to the DRS CAN bus network.
Note that the CAN bus network connected to the DRS is its own independent CAN bus
backbone and needs to be terminated at both ends by a terminating resistor. A 120
Ohm resistor is standard supply with the DRS to terminate the CAN bus. For example,
if you install a SC-30/WS-200 with the DRS CAN bus port, you must have two termi-
nators on the backbone. One can be at the sensor and the other located inside the
DRS as shown in the inset at right.
Refer to the DRS Installation Manual for more information about connection.
TZT9
TZT9
TZT14
TZT14
Resistor assembly
(120 OHM-1007#24-L50,
supplied with DRS)
Twisting and
soldering
White
Blue
CAN bus cable
In the above example, the terminating resistors are
necessary at DRS and SC-30.
WS-200 SC-30
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Furuno TZT14 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Furuno TZT14 in the language / languages: English as an attachment in your email.

The manual is 45,75 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Furuno TZT14

Furuno TZT14 User Manual - English - 16 pages

Furuno TZT14 User Manual - English - 250 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info