34
5. As a final test, move the boat towards a
small buoy and confirm that the buoy
shows up dead ahead on the radar when it
is visually dead ahead.
Adjusting sweep timing
(Adjustment range:0.000~4.266nm)
This adjustment ensures proper radar perfor-
mance, especially on short ranges. The radar
measures the time required for a transmitted
echo to travel to the target and return to the
source. The received echo appears on the dis-
play based on this time. Thus, at the instant
the transmitter is fired, the sweep should start
from the center of the display (sometimes
called sweep origin.)
A trigger pulse generated in the display unit
goes to the antenna unit through the signal
cable to trigger the transmitter (magnetron).
The time taken by the signal to travel up to
the antenna unit varies, depending largely on
the length of signal cable. During this period
the display unit should wait before starting
the sweep. When the display unit is not ad-
justed correctly, the echoes from a straight
local object (for example, a harbor wall or
straight pier) will not appear with straight
edges - namely, they will be seen as “pushed
out” or “pulled in” near the picture center. The
range of objects will also be incorrectly
shown.
(1) Correct
(2) Target pushed
inward
(3) Target pushed
outward
Figure 6-24 Examples of improper and
correct sweep timing
1. Transmit on the shortest range and confirm
that the [GAIN] and [A/C SEA] controls
are properly adjusted.
2. Visually select a target which forms straight
line (harbor wall, straight pier).
3. Select “10. Sweep Timing Adjustment” on
the installation setup menu and press the
[ACQ/ENTER] key. The message appears.
[ Sweep Timing Adjustment ]
Use omnipad to straighten
target and press ENTER key.
Correction 0.000 nm
<Press MENU for inst setup>
Figure 6-25 Sweep timing adjustment
message
4. Operate the omnipad to straighten the tar-
get selected at step 2, and then press the
[ACQ/ENTER] key.
Adjusting MBS
(Adjustment: 0.00~0.25)
Main bang (black hole), which appears at the
display center on short ranges, can be sup-
pressed as follows.
1. Transmit on long range about 10 minutes.
2. Adjust the gain to show a small amount of
noise on the display.
3. Change to the 0.125 nautical mile range
and adjust the [A/C SEA] control.
4. Select “11. MBS adjustment” on the instal-
lation setup menu.
5. Press the [ACQ/ENTER] key. The follow-
ing message appears.
[ MBS Adjustment ]
Set value by omnipad
and press ENTER key.
Correction 000
<Press MENU for inst setup>
Figure 6-26 MBS Adjustment message
6. Operate the omnipad to suppress main
bang. (left: low, right: high, between 0 and
25)
7. Press the [ACQ/ENTER] key.
45


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Furuno 1942 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Furuno 1942 in the language / languages: English as an attachment in your email.

The manual is 1,39 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Furuno 1942

Furuno 1942 User Manual - Spanish - 53 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info