of the Remote Control will immediately initiate a Full Alarm
condition whether the system is Armed or Disarmed. The
alarm can be cancelled by pressing the ‘DISARM’ button
on the Remote Control or via the Control Panel.
Any number of Remote Control Units can be used with
your system, providing they are all coded with the
system House Code.
The Remote Control is powered by a CR2032 type
Lithium cell which under normal conditions will have an
expected life in excess of 1 year. Under normal battery
conditions the LED on the Remote Control will only
illuminate when a button is pressed. However, under
low-battery conditions this LED will continue to flash
after the button has been released. When this occurs the
battery should be replaced as soon as possible.
CONFIGURING THE REMOTE
CONTROL
1.
Remove the rear cover by undoing the small screw
on the rear of the Remote Control.
2. Select and record a random combination of ‘ON’ and
‘OFF’ positions for the DIP switches. This will be the
system House Code that enables all elements of your
transmitters to communicate with the Control Panel.
3.
Ensure that the jumper link located immediately
below the House Code DIP switches is fitted in
position for use with this alarm system.
4.
Insert the battery under the clip ensuring that the
+ve terminal faces upwards away from the PCB.
5. Replace the rear cover and fixing screw. Do not over
tighten the screw as this could damage the thread.
CONTROL PANEL
Outside View of Control Panel
POSITIONING THE CONTROL PANEL
When choosing a suitable location for the Control
Panel, the following points should be considered.
1.
The Control Panel should be located in a position out
of sight of potential intruders and in a safe location,
but easily accessible for system operation.
2.
The Control Panel should be mounted on a sound
flat surface to ensure that the rear tamper switch on
the Control Panel is closed when the Panel is
mounted. The Control Panel should be mounted at
a convenient height of between 1.5 and 2m and in
a position where it will be seen each day.
Note: If small children are in the household, a
further consideration should be given to keeping
the units out of their reach.
3. It is recommended that the Control Panel should
be positioned such that the Exit/Entry tone
(emitted by the Control Panel) can be heard from
outside the property.
4.
The Control Panel should be mounted within a
protected area so that any intruder cannot reach
the Control Panel without opening a protected
door or passing through an area protected by a PIR
movement detector when the system is armed.
5. The Control Panel must be located within reach
of a mains socket.
6. If the telephone based functionality is to be used
then the Control Panel will need connecting to a
convenient telephone point.
Note: It is recommended that the telephone
connection lead is not extended beyond 5m
INSTALLATION
House Code
DIP Switches
Jumper Link
Battery Clip
Battery
LCD Displa
y
Window
Status LED
s
Keypad
ESC
ENTER
2
6
7
9
#
*
8
5
3
1
4
0
SA5 9
IMPORTANT: The House Code for your
system should be changed from the factory
default setting
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Friedland SA5 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Friedland SA5 in the language / languages: English as an attachment in your email.

The manual is 0,4 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info