6
The chime does not work…
● Check that the batteries are the correct type, LR14 ‘C’ cells. Only use alkaline batteries.
● Check that the batteries are fitted correctly.
● The chime could be out of range of the bell push. Try the chime in a different location.
● The chime might not have learnt the identity of the bell push. Follow the programming procedure.
The chime does not sound…
● Check the chime switch position.
● Check that the volume control is not at the minimum setting.
The flashing light does not work…
● Check the chime switch position.
Range is reduced…
● Metal structures, including uPVC door frames can reduce the range of the product.
Avoid mounting the push or chime on or near metal structures.
● Other equipment can cause radio interference that affects your chime.
● Walls and ceilings will reduce the range.
● Weak batteries will reduce range. Replace every 12 –18 months. In cold conditions (below 5ºC),
batteries may need to be replaced more often.
Amber light flashes…
● When the chime battery is low, an amber light will flash every 5 seconds. Fit new batteries in the
chime, type LR14 ‘C’ cells. Only use alkaline batteries.
Chime/Push does not work with my older Libra equipment…
● Libra + is not compatible with the earlier Libra system.
● Only use accessories marked Libra +.