With chains
1. Drill holes with a 5 mm diameter bit and x
the wall brackets in the ceiling. Fig.2.
2. Mount the two supports on the aluminum
tube on the back of the unit. Fig.3.
3. Mount the supplied S-hooks on both ends of
the chains and hang the unit. Fig.5.
With hinged arm INFHA05 (accessory)
Hinged arm INFHA05 should not be used in
areas where there is a high risk of earthquakes
or strong winds.
1. Assemble all parts securely with screws and
nuts. Fig.6.
2. Make sure that the cable does not get caught
between the various components.
3. Fix the wall brackets to INFHA05. Fig.7A.
4. Mount the two supports to the aluminum
tube on the back of the unit approx. 25 cm
apart. Fig.3.
5. With the supplied screws, lock the supports in
the right angle on the wall brackets. Fig.7B-C.
On post IHP with bracket INFP (accessories)
1. Fix the wall brackets to INFP. Fig.8A.
2. Open INFP and place around the post IHP.
Fig.8B.
3. Insert the knob and screw until it is
completely locked. Fig.8C.
General Instructions
Read these instructions carefully prior to
installation and use. Keep this manual for
future reference.
The product may only be used as set out in
the assembly and operating instructions. The
guarantee is only valid should the product be used
in the manner intended and in accordance with
the instructions.
Application
Infraex is a versatile patio heater with several
mounting options and is well suited for
temporary heating at events or patios. Infraex
provides immediate heat when turned on and
cools off quickly when switched off.
Protection class: IP55.
Positioning
The heaters must be placed so that they cover
the area to be heated. Optimum comfort is
achieved if the heat is distributed from at
least two directions. Fig.1. A rule of thumb for
infrared heaters is that 600–800 W/m² increases
the experienced temperature by about 10 °C.
The output demand can be reduced if the
area to be heated is protected. If the area
only has a roof, at least 800 W/m² should be
installed. 600 W/m² is sucient if the area has
three walls. For enclosed areas, the output
demand must be calculated. The recommended
installation heights for the heater are shown on
the introduction pages.
Mounting
Infraex can be installed directly on a wall,
with a hinged arm from the wall, with chains
from the ceiling or on a post. Wall brackets and
chains are included in delivery. The heater can
be angled in several xed positions.
For minimum distance, see diagrams on
introductory pages.
Wall mounting
1. Drill holes with a 5 mm diameter bit in the
wall and x the wall brackets. Fig.2.
2. Mount the two supports on the aluminum
tube on the back of the unit. Fig.3.
3. With the supplied screws, lock the supports
in the right angle on the wall brackets. Fig.3.
Fig.4.
Connection
Infraex is equipped with a 1.9 metre cord with
plug for connection to an earthed outlet socket.
The connection cord must not rest against the
unit as the surface becomes hot or can be hit by
thermal radiation. Contact an electrician if the
cord needs to be changed. Note that due to the
high temperatures in the heater, a cord of the
type H05RN-F or the like should be used.
As the halogen lamp has a high starting
current the wall socket should be fuse
protected by a slow burn fuse.
In the event of uncertainty contact an
electrician.
Control
The heater is controlled with the included
remote control (on/stand-by), or the built-in
push button. The remote control can activate
several heaters.
Use included 2 x LR1 batteries for the remote
control. Remove batteries when not in use
for an extended period in order to preserve
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Frico Infraflex at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Frico Infraflex in the language / languages: English as an attachment in your email.

The manual is 2.22 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Frico Infraflex

Frico Infraflex User Manual - German - 10 pages

Frico Infraflex User Manual - Dutch - 10 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info