787187
4
Zoom out
Zoom in
Previous page
1/6
Next page
ELIR
6
GB
General instructions
Read these instructions carefully before
installation and use. Keep this manual for
future reference. During installation and
maintenance and when replacing the lamp
the heater should always be disconnected
from the power supply.
The element of ELIR is a halogen quartz
lamp that is operating at about 2200 ºC. The
expected lifetime of the lamp is depending
on the ambient temperature and where the
heater is installed. When it is mounted airy
and outdoor the lamp will live longer.
The guarantee is only valid if the heater is
installed and used in a way that is described
in this instruction.
Application area
This infrared heater is tested and approved
according to the EMC- and LVD regulations
and is CE compliant. Thanks to the high
protection class IP65 it is suitable for
installation outdoors.
Normally ELIR is used to give comfort for
people in the area in front of or under the
heater, but it can also be used for drying. The
wet surface will be heated by the radiation
and the evaporation goes faster.
In winter ELIR also can be used for
defrosting purposes.
Mounting
After unpacking make sure that the appliance
is complete and shows no signs of visible
damage.
Make sure that the voltage is the same as
indicated on the rating label.
ELIR must be mounted at least 1,8 m above
the floor.
When the heater is mounted at 2 – 3 m
height on a wall the heat radiation covers
approximately an area of 2,5 x 4 m. The best
comfort is experienced when a person is
heated from two directions.
Enclosed in the package there is a wall
bracket. Make sure that the wall is firm and
that proper screws are used.
Fig. 2-4 show other mounting alternatives.
The parts needed for such installations are to
be purchased separately.
Following important notes must be followed:
- The heater should always be installed
horizontally and only by using the brackets
provided.
- The heater must not be located directly
below a wall socket.
- The minimum distances according to page
2 must be kept.
- Do not use the heater directly near a
bathtub, a shower or a swimming pool.
- The heater must not be installed in areas
where hazardous vapours may be present.
Electrical installation
The electrical installation should be
carried out by a qualified electrician and in
conformity with prevailing regulations. When
fixed an all-pole switch with at least 3 mm
breaking gap should precede the appliance.
If a cable connects the heater it should be of
type H05 RN-F 3 x 1 or similar.
N.B: The cable glands must be classified as
the heater.
Start up (E)
When the unit is used for the first time or
after a long period of disuse, smoke or odour
may result from dust or dirt that has collected
on the element. This is completely normal
and disappears after a short time.
Operation
- All users should be made aware of all
aspects of operation and safety mentioned
in this instruction.
- The appliance is only to be used according
to these instructions.
- Children or incompetent persons must not
use this appliance.
- Do not touch the heater with wet hands or
with bare feet.
Mounting and operating instructions
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Frico ELIR12 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Frico ELIR12 in the language / languages: English as an attachment in your email.

The manual is 0.57 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info