markings identifying the terminals in your plug, proceed as follows.
- The wire which is coloured green and yellow must be connected to the terminal in the plug which is
marked with the letter E or by the earth symbol or coloured green or green and yellow.
- The wire which is coloured blue must be connected to the terminal which is marked with the letter N
or coloured black.
- The wire which is coloured brown must be connected to the terminal which is marked with the letter
L or coloured red.
ATTENTION: Do not forget to use adequate plugs to the support brackets. Enquire after the manu-
facturers. Do an embedding if necessary. The manufacturer accepts no responsibility in case of a
faulty hanging due to the drilling and the setting up of plugs in the ceiling.
1) Unpack the hood parcel.
• LAYING OUT BEFORE FITTING THE HOOD
2) Mark the centre of the cooking appliance onto the ceiling with a plumb line. Draw the horizontal axes
running parallel to the stove top onto the ceiling as illustrated Fig. 1.
3) Place the drill gauge centred on the axes aligning the axes on the drill gauge centrally over these axes
as illustrated Fig. 2b.
4) Remove the self-tapping screws, which x the chimney item 7 to the metal frame bracket as illustrated
in Fig. 2a and then remove both sides of the upper chimney stacks.
5) Unplug the connector and separate the motor housing from the canopy unscrewing the screws TH 5 x
16.
FITTING THE CANOPY BRACKET
6) Mark the positions on the ceiling for : - The cut-out for the ducting Ø 150 mm in the extraction mode
and Ø 200 mm in the remote mode when ducting runs through the ceiling.
- The mains supply cords.
- The 4 xing holes for Ø 10 mm nuts and bolts.
Drill the different holes with the appropriate masonry bit. When xing the cooker hood to a plasterboard
ceiling ensure it is reinforced as illustrated in Fig. 3 and attach using four Ø10mm nuts and bolts; ensuring
the bolts as sleeved between the plasterboard and the joist supports to prevent the ceiling being damaged
when the bolts are tightened up.
If the ceiling is concrete, use eight Ø 10 mm steel rawl bolts. Plastic rawl plugs must not be used.
7) Remove the deector Fig. 4.
8) The height of the cooker hood can be adjusted in 50 mm stages. 650 mm when tting above an electric
hotplate and 700 mm when tting above a gas hotplate. Select the height required using the measure-
ments illustrated in Fig. 5 and x the metal diffuser to the frame of the chimney brackets using the height
5 x 10T hexagonal headed screws. A drawing on the drill gauge denes the positioning for the controls.
9) Check the vertical of the chimney.
• DUCTING
The hood is more effective when used in the extraction mode (ducted to the outside). When the cooker
hood is ducted to the outside, charcoal lters are not required.
The ducting used must be 150 mm (6 INS), rigid circular pipe and must be manufactured from re retard-
ant material, produced to BS.476 or DIN 4102-B1. Wherever possible utilise rigid circular pipe which has
a smooth interior, rather than the expanding concertina type ducting.
Maximum length of ducting run:
- 4 metres with 1 x 90° bend.
- 3 metres with 2 x 90° bends.
- 2 metres with 3 x 90° bends.
The above assumes our 150 mm (6 INS) ducting is being installed. Please note ducting components and
ducting kits are optional accessories and have to be ordered, they are not automatically supplied with the
chimney hood.
IN THE EXTRACTION MODE:
a. Fit the non-return backow aps C over the round outlet item 6 on top of the canopy while pressing
down until they snap into position, and then connect the ducting 150mm (6 INS) and secure the connec-
tions with appropriate clamping rings or adhesive tape (Fig. 8).
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Franke Florida Centrale at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Franke Florida Centrale in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 39,87 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info