Operating the Meter from the Front Panel
Power-Up Configuration 3
3-25
Range mode on primary display (manual or autorange)
Measurement rate (slow, medium, fast)
Dual display status (active or inactive)
Any combination of selected function modifiers
Touch Hold level (1, 2, 3, 4)
Last recorded minimum and maximum values for MINMAX modifier
Last recorded relative base
Relative base shown in secondary display (enabled or disabled)
Last HI-LO settings in compare mode
Trigger mode (1, 2, 3, 4, 5)
Echo setting (on or off)
dB and dB reference
RS-232 settings
PRINT mode
Data format (with or without UNIT) sending through the RS-232
Power-Up Configuration
When the Meter is turned on and the power-up sequence is complete, the Meter defaults
to the power-up configuration listed in Table 3-9.
The RS-232 baud rate, parity, and echo mode are not changed when power is cycled off
and on. These parameters remain as set until changed by the user.
Table 3-9. Factory Power-Up Configuration
Parameter Configuration
Function setting DC volts
Range mode Autorange
Reading rate Slow (2.5 readings/second)
Touch Hold sensitivity level 1 (5 % of reading)
High/low values for Compare mode (COMP) 0
Minimum and maximum values in MIN MAX modifier 0
Relative base 0
Relative base in secondary display Disabled
Trigger type 1 (Internal)
Trigger type 0
Calibration
Refer to the 8808A Calibration Manual for instructions on calibrating the Meter.
59


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fluke 8808A at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fluke 8808A in the language / languages: English as an attachment in your email.

The manual is 1,96 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Fluke 8808A

Fluke 8808A User Manual - German - 102 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info