Reference Multimeter and 8 ½ Digit Multimeter
Guidelines to Avoid Measurement Errors
125
Guidelines to Avoid Measurement Errors
To avoid errors, see Table 25.
Table 25. Guidelines to Avoid Errors
Sources of Inaccuracy Avoiding or Minimizing Inaccuracy
Thermal EMFs can cause series (Normal) mode
interference, particularly where large currents
have a heating effect at junctions. In otherwise
thermoelectrically-balanced measuring circuits,
cooling caused by drafts can upset the balance.
Screen thermal junctions from drafts.
Before taking readings allow time for thermal
equilibrium to be reached.
Use conductors, joints and terminals with a
good margin of current-carrying capacity.
Avoid thermoelectric junctions where
possible:
o Use untinned single-strand copper wire of
high purity.
o Avoid making connections through Nickel,
Tin, Brass and Aluminum. If oxidation is a
problem, use gold-plated copper
terminals, and replace the terminals
before the plating wears off.
o If joints must be soldered, low-thermal
solders are available, but crimped joints
are preferred.
o Use low-thermal switches and relays
where they form part of the measuring
circuit.
o Balance one thermal EMF against another
in opposition, where possible. (Switch and
relay contacts, terminals, etc.)
129


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fluke 8588A at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fluke 8588A in the language / languages: English as an attachment in your email.

The manual is 1,84 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Fluke 8588A

Fluke 8588A User Manual - German - 134 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info