Clamp Meter
Basic Measurements
13
Power Quality Indicator (378/378 FC)
The Power Quality indicator shows that the ratio of the real power
compared to the apparent power or harmonic distortion is outside
the optimal range.
To setup:
1. Turn the control knob to U.
2. Connect the Clamp to ground with the ground lead.
If the total harmonic distortion or the power factor is outside
the optimal range, the related indicator shows on the display:
P
Q
R
Fluke Connect software supports the Power Quality indicator.
The Power Quality indicator sensitivity is adjustable:
For information about how to set the sensitivity, see Power-On
Options.
AC/DC Voltage Measurement with Test Leads
To measure ac or dc voltage:
1. Turn control knob to V or N.
2. Connect the black test lead to the COM terminal and the red
test lead to the VX terminal.
3. Touch the probes to the test points of the circuit.
The display shows the measurement.
Note
Use B to toggle on/toggle off the mV function
shown in yellow at the control knob position.
Resistance/Continuity
To measure resistance or continuity:
1. Turn the control knob to D.
2. Remove power from the circuit to test.
3. Connect the black test lead to the COM terminal and the red
test lead to the VX terminal.
4. Touch the probes to the test points of the circuit.
The display shows the measurement.
If the resistance is <30 Ω, the beeper sounds continuously to
indicate continuity. If the display shows OL, the circuit is open.
To disable the beeper, see Power-On Options.
Function
Sensitivity
High Medium Low
PQ-Amps 10 % THD 25 % THD 50 % THD
PQ-Volts 8 % THD 10 % THD 15 % THD
PQ-PF 0.9 0.75 0.6
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fluke 378 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fluke 378 in the language / languages: English as an attachment in your email.

The manual is 2,02 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Fluke 378

Fluke 378 User Manual - German - 22 pages

Fluke 378 User Manual - Dutch - 22 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info