32
Duty Cycle Measurements
Duty cycle (or duty factor) is the percentage of time a
signal is above or below a trigger level in one cycle
(Figure 9). The duty cycle mode is optimized to measure
the on or off time of logic and switching signals. Systems
such as electronic fuel injection systems and switching
power supplies are controlled by pulses that have
different widths, which can be measured by a duty cycle
measurement.
To measure duty cycle, set up the Product to measure
frequency. Then push G a second time. As with the
frequency function, push E to change the slope for
the counter.
For 5-V logic signals, use the 6-V dc range. For 12-V
switching signals in automobiles, use the 60 V dc range.
For sine waves, use the lowest range that does not result
in multiple triggers. (Normally, a distortion-free signal can
be up to 10x the amplitude of the selected voltage range.)
If a duty cycle measurement is unstable, push MIN MAX
and then scroll to the AVG (average) display.
-Slope
Trigger Point
+Slope
Trigger Point
30% Above
+Slope 70% Below
-Slope
100%
iyf.eps
Figure 9. Components of Duty Cycle Measurements
38


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fluke 28 II Ex at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fluke 28 II Ex in the language / languages: English as an attachment in your email.

The manual is 5,75 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Fluke 28 II Ex

Fluke 28 II Ex User Manual - German - 58 pages

Fluke 28 II Ex User Manual - Dutch - 58 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info