28 II Ex
Users Manual
30
Frequency Measurements
For frequency measurements, the Product counts the
number of times the signal crosses a set voltage level
each second.
Table 7 summarizes the trigger levels and applications for
frequency measurements in the ranges of the voltage and
current functions of the Product.
To measure frequency, connect the Product to the signal
source. Next, push G. When you push E, the
trigger slope switches between + and -, as shown by the
symbol at the left side of the display (refer to Figure 9
under "Duty Cycle"). Push D to stop and start the
counter.
The Product autoranges to one of five frequency ranges:
199.99 Hz, 1999.9 Hz, 19.999 kHz, 199.99 kHz, and
>200 kHz. For frequencies less than 10 Hz, the display is
updated at the frequency of the input. Less than 0.5 Hz,
the display can be unstable.
Some guidelines for frequency measurements are:
If a measurement shows as 0 Hz or is unstable, the
input signal can be below or near the trigger level. To
correct these problems, go to a lower range, which
increases the sensitivity of the Product. In the
function, the lower ranges also have lower trigger
levels.
If a measurement is a multiple of what you expect,
the input signal can be distorted. Distortion can
cause multiple triggers of the frequency counter.
Select a higher voltage range to decrease Product
sensitivity and try to repair this problem. You can
also set a dc range to increase the trigger level as a
possible solution. In general, the lowest frequency
shown in the display is the correct one.
36


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fluke 28 II Ex at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fluke 28 II Ex in the language / languages: English as an attachment in your email.

The manual is 5,75 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Fluke 28 II Ex

Fluke 28 II Ex User Manual - German - 58 pages

Fluke 28 II Ex User Manual - Dutch - 58 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info