ScopeMeter® Test Tool
MDA-550-III Test Tool
71
Motor Shaft
The Motor Shaft function detects bearing flash-over that can damage motor bearings. The
measurement requires a connection to the rotating shaft of the motor. For this measurement,
brushes are included as accessories. Alternatively, you can use a stranded wire probe. Fluke
recommends the VP410 10:1 Voltage Probe. See Figure 35.
Figure 35. Motor Shaft Test Setup
W Caution
For safety, stop the motor.
To s e t u p:
1. Remove the black protective cap and black insulation sleeve from the probe tip.
2. Place the brush on top of the voltage probe.
3. Turn the screw to tighten the brush on the probe.
4. Place the probe in the magnetic probe holder. Extend the probe holder with the included two-
piece extension rod.
Note
Use the probe holder to keep the probe in a fixed position and the brush in contact with
the motor shaft.
5. Make sure that it is possible to make good electric contact with the shaft before you do the
measurement.
A
B
Voltage Probe
Magnetic Probe Holder
77


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fluke 190-502-III at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fluke 190-502-III in the language / languages: English as an attachment in your email.

The manual is 9.23 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info