775826
56
Zoom out
Zoom in
Previous page
1/98
Next page
190 Series III
Users Manual
50
Missing Pulses
The next example is about how to find missing pulses in a train of positive pulses. In this
example, it is assumed that the pulses have a 100 ms distance between the rising edges. If the
time accidentally increases to 200 ms, a pulse is missing.
To set the test tool to trigger on such missing pulses, let it trigger on gaps bigger than 110 ms:
1. Press T to show the TRIGGER key labels.
2. Press 4 to open the TRIGGER OPTIONS menu.
3. Use the cursor and E to select Pulse Width on A and open the TRIGGER ON PULSE
WIDTH menu.
4. Use the cursor and E to select the positive pulse icon to trigger on a positive pulse, then
jump to Condition.
5. Use the cursor and E to select >t and jump to Update.
6. Use the cursor and E to select On Trigger and exit the menu.
The test tool is now prepared to trigger on pulses that are more than a selectable time in
duration. Observe that the trigger menu at the bottom of the screen has been adapted to set the
pulse condition. See Figure 30.
To set the pulse width to 400 μs:
7. Press 1 to enable the cursor and adjust the pulse width.
8. Use h i to select 400 μs.
Figure 30. Trigger on Missing Pulses
56


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fluke 190-102-III at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fluke 190-102-III in the language / languages: English as an attachment in your email.

The manual is 9.23 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info