32
Harmonics Grouping
The Harmonic Grouping selection at the bottom of the screen allows for a different method of
harmonics representation. The listed standards most frequently recommend Subgrouped
harmonic.
Note
Fluke recommends the Subgrouped setting unless there are special circumstances
why the other methods are applicable for the required test. A change to this grouping
method could lead to inconsistent results when making comparisons of other
measurements made at the same or other locations.
Select Done to exit the Harmonics Grouping screen.
Mains Signaling
Mains signaling, or ripple control, is a technique used by utilities to instruct revenue meters to
switch tariffs, turn on street lighting, or turn on other loads. The mains signaling selection
enables capture of two signal frequencies other than the system frequency. The frequencies
must be specified in the setup and between 110 Hz and 1600 Hz.
To set the Mains Signaling voltage:
1. Enter the value in the Frequency 1 and Frequency 2 fields.
After you enter the frequency, the Enable radio button is automatically checked as active.
2. Tap Done.
This measurement is increasingly rare. If you do not need this information, ignore the setup.
The selection is switched off as a default.
Note
See the Glossary for more information about these configuration effects and details of
the triggering mechanisms.
AUX
The auxiliary, or analog, inputs are dc inputs that have a physical socket on top of the Analyzer
reserved for ±10 V dc signals. These signals may be from transducers that output voltage or
current. Each analog input signal can be labeled to describe the signal along with the
applicable engineering units, such as V dc, V ac, I ac, °C, or Nm. Select a gain and an offset to
scale the 0 V to 10 V signal so that the display shows the correct values.
38


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fluke 1777 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fluke 1777 in the language / languages: English as an attachment in your email.

The manual is 3.36 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info