True RMS Multimeters
Display
3
Display
8
7
7
6
4
5
3
2
1
13
14
15
9
10
11
12
aej02f.eps
No. Symbol Meaning
1
s
Meter is set to continuity function.
2
R
Diode test.
3
O
Negative readings.
4
Y
Unsafe voltage. Voltage 30 V, or
voltage overload condition (OL).
5
K
Display HOLD is enabled. Display
freezes present reading.
In MIN MAX AVG mode, MIN MAX
AVG recording is paused.
6
M
X W V
MIN MAX AVG mode enabled.
Maximum, minimum, or average
reading displayed.
No. Symbol Meaning
7
nµF
mVA
Mk
e kHz
Measurement units.
8
DC AC
Direct current, alternating current.
9
N
Replace battery immediately.
10
610000 mV
All possible segments of the range
annunciator.
11
(Bar graph)
Analog display.
12
Auto Range
Manual Range
The Meter selects the range with the
best resolution.
The user selects the range.
13
±
Bar graph polarity.
14
0L
The input is too large for the range.
15
LEAd
WTest lead alert.
Displayed briefly when rotary switch
is moved to
or from any A position.
Error Messages
diSC
Displayed while the capacitor discharges. In
Capacitance function only.
EEPr
Cannot read data from EEPROM. Turn power off,
then on. If message remains, service Meter.
EEPr
Err
Invalid EEPROM data. Have Meter serviced.
CAL
Err
Invalid calibration data. Calibrate Meter.
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fluke 110 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fluke 110 in the language / languages: English as an attachment in your email.

The manual is 0,65 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Fluke 110

Fluke 110 User Manual - English - 22 pages

Fluke 110 User Manual - German - 22 pages

Fluke 110 User Manual - Dutch - 22 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info