Function Range Resolution Model 110 Model 111 Model 112
DC Amps
8
(Models 111 and 112)
6.000 A
10.00 A continuous or
20 A overload for 30
seconds maximum
0.001 A
0.01 A
NA 1.0 % + 3 1.0 % + 3
Hz
7
(V or A input ) 99.99 Hz
999.9 Hz
9.999 kHz
50.00 kHz
0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1 % + 2
0.1 % + 2
0.1 % + 2
MIN MAX AVG Accuracy
and Response Time
Accuracy is the specified accuracy of the measurement function ± 12 digits for changes >275 ms in duration
(± 40 digits in AC). Typical response time: 100 ms to 80 % of signal, except V AC and A AC.
1. All AC voltage ranges are specified from 5% of range to 100% of range. Because inputs below 5% of range are not specified, it is normal for this
and other True RMS meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together.
2. Crest factor of ≤ 3 at full scale up to 300 V, decreasing linearly to crest factor ≤ 1.5 at 600 V.
3. For non-sinusoidal waveforms, add -(2% reading + 2% full scale) typical, for crest factors up to 3.
4. The 6000 mV range can only be entered in Manual Range mode.
5. For film capacitors.
6. Crest factor of ≤ 3. AC current is not specified below 3A. It is normal for this and other True RMS meters to display non-zero readings when the test
leads are disconnected from a circuit or are shorted together.
7. Hz is specified from 5 Hz to 50 kHz in volts, from 50 Hz to 5 kHz in amps.
8. Amps input burden voltage (typical): 400 mA input 2 mV/mA, 10 A input 37 mV/A
.
Function Input Impedance (Nominal) Common Mode Rejection Ratio Normal Mode Rejection
Volts AC > 5 MΩ < 100 pF > 60 dB at DC, 50 Hz or 60 Hz
Volts DC > 10 MΩ < 100 pF > 100 dB at DC, 50 Hz or 60 Hz > 50 dB at 50 Hz or 60 Hz
Full Scale Voltage
Open Circuit Test Voltage To 6 MΩ 40 MΩShort Circuit Current
Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.
Product:
Forumrules
To achieve meaningful questions, we apply the following rules:
First, read the manual;
Check if your question has been asked previously;
Try to ask your question as clearly as possible;
Did you already try to solve the problem? Please mention this;
Is your problem solved by a visitor then let him/her know in this forum;
To give a response to a question or answer, do not use this form but click on the button 'reply to this question';
Your question will be posted here and emailed to our subscribers. Therefore, avoid filling in personal details.
Register
Register getting emails for Fluke 110 at:
new questions and answers
new manuals
You will receive an email to register for one or both of the options.
Get your user manual by e-mail
Enter your email address to receive the manual of Fluke 110 in the language / languages: English as an attachment in your email.
The manual is 0,65 mb in size.
You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.
If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.
The email address you have provided is not correct.
Please check the email address and correct it.
Your question is posted on this page
Would you like to receive an email when new answers and questions are posted? Please enter your email address.