motor fuels) or explosive liquids, salt
water, cleaning agents and foodstuffs is
not permitted. Liquid temperature not to
exceed 35°C.
Store the equipment in a dry place and
out of reach of children.
Caution! To avoid damage to the
equipment and any possible person
injury resulting from this:
Do not work with damaged or incom-
plete equipment, or with equipment
that has been converted without the ap-
proval of the manufacturer. Before initial
operation, have a specialist check that
the required electrical protection meas-
ures are in place.
• Donotcarryorxtheequipmentbythe
cable or pressure line.
Protect the equipment from frost and
from running dry.
Use only original accessories and do
not carry out conversion work on the
equipment.
Please read the notes in the operating
instructions on the topic of “mainte-
nance and cleaning”. Any measures
above and beyond these, particularly
opening the equipment, are to be car-
ried out by an electrician. In the case
of repairs, always contact our service
centre.
Electrical safety:
Caution: to avoid accidents and inju-
ries from electric shocks:
After erection, the mains plug must be
freely accessible when the equipment is
in operation.
Before operating your new pump, have
a specialist check:
- The earthing, the protective multiple
earthing; the residual current circuit
breaking must be compliant with the
safety regulations of the energy supply
company and function without fault,
- The protection of the electrical plug
connections from the wet.
- Ifthereisariskofooding,xthe
plug connections in an area that is
safefromooding.
Ensure that the mains voltage matches
thespecicationsontheratingplate.
The electrical installation shall be ac-
cording to national wiring rules.
Connect the equipment only to a sock-
et with a residual current protection
device (residual current circuit breaker)
with a rated current of not more than
30 mA; minimum fuse 10 amperes.
Before each use, check the equipment,
cable and plug for damage. Defective
cables are not to be repaired, but rath-
er replaced by new ones. Have any
damage to your equipment repaired
by a specialist.
If the power cable for this equipment is
damaged, it must be replaced by the
manufacturer, a customer service agent
ofthesameorasimilarlyqualiedper-
son in order to prevent hazards.
Do not pull the plug from the socket by
the cable. Protect the cable from heat,
oil and sharp edges.
• Donotcarryorxtheequipmentby
the cable.
Use only extension cables that are pro-
tected from spray water and designed
for outdoor use. Always fully unroll a
cable drum before use. Check the ca-
ble for damage.
Before any work on the equipment,
during work breaks and in the case
of non-use, remove the plug from the
socket.
The cross-section of mains connection
lines must be no smaller than rub-
ber hose lines with the designation
H07RN-F. The line must be 10 m long.
7


Need help? Post your question in this forum.

Forumrules
1

Forum

florabest-fgps-1100-b2

Reset search

  • I have a FGPS 1100 C4 Florabest pump. It runs fine after filling the primer end but cuts off after about 30 minutes of running a sprinkler. I have to then refill the primer reservoir and wait about 30 minutes before the pump will restart. I have to repeat the procedure about every 30 minutes. What's the problem? Submitted on 7-7-2020 at 20:14

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Florabest FGPS 1100 B2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Florabest FGPS 1100 B2 in the language / languages: English, German, Dutch, French, Swedish, Finnish as an attachment in your email.

The manual is 2,27 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info