456443
17
Zoom out
Zoom in
Previous page
1/20
Next page
40069 Zola Predosa (BO) - ITALY
info@finicompressors.it
- GB -
5.12 DTT11 ELECTRONIC INSTRUMENT (DIGITAL TIMER THERMOMETER)
set
Button - access the set-up.
Button - condensate drain test / value increment.
ON
set
LED -
-
glowing = power on.
flashing = set-up condition.
ON
set
set
DISPLAY
LED - condensate drain solenoid valve on.
The DTT11 controller performs a double function : it shows the current operating DewPoint through the
digital led display and it controls the functioning of condensate drain solenoid valve through the cyclic
electronic timer.
OPERATION - During the dryer operation, the LED
ON
set
is on.
The 10 LED display indicates the current operating DewPoint, shown by means of a three colours (blue-
green-red) bar over the display itself.
Blue section - the operative DewPoint of the dryer is low;
Green section - operating conditions ensuring an optimal DewPoint;
Red section - DewPoint of the dryer too high, the treatment of the compressed air may be improper.
The condensate drain solenoid valve is activated for 2 seconds (T
ON
) - LED on - each minute (T
OFF
), if
standard setting.
To perform the manual test for the condensate drain, press the
button.
The "out of scale" conditions are indicated by the intermittent flashing of the first and the last LED of the
display, respectively showing the exceeding of the lower or the upper range.
SET-UP - The DTT11 is adjusted during the final test of the dryer. In case of particular requirements
concerning the operation management, the user can change the setting of the programmed parameters.
The parameters which can be set up are the following :
T
ON
- activation time of the condensate drain solenoid valve.
T
OFF
- pause time between two consecutive activation of the condensate drain solenoid valve.
To access the set-up, keep pressed the
set
button for at least 2 seconds;
ON
set
LED flashing confirms the command.
First appears the T
ON
parameter; to access the other parameters, press sequentially the
set
button.
To change the value of the selected parameter, keep pressed the
set
button and operate on button ;
the current value is shown on the LED display. For the value range and the resolution (value of each single
LED), see the following table :
Parameter Description Display Value
range
Resolution Set
value
T
ON
Activation time of the
condensate drain solenoid valve
Synchronous flashing
LED
ON
set
+LED
1 - 10 sec 1 sec 2 sec
T
OFF
Pause time of the condensate
drain solenoid valve
Non-synchronous flashing
LED
ON
set
+LED
1 - 10 min 1 min 1 min
To exit the set-up condition in any moment, press the button. In case no operations are made during 2
minutes, the system exits automatically the set-up condition.
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Finicompressors Artic 134-EVO luchtdroger at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Finicompressors Artic 134-EVO luchtdroger in the language / languages: English as an attachment in your email.

The manual is 1,04 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info