584956
6
Zoom out
Zoom in
Previous page
1/56
Next page
Ferm6
GB
For general use you can use an “all
temperature” oil 10W-30
≤0°C SAE#10
0°C–25°C SAE#20
25°C–35°C SAE#30
≥35°C SAE#40
Filling up the tank
• Usepetrolmixtureonly
• Removeanypowercords
• Turnpowerswitchesoff
• Donotoverfill–leaveairgapattopoffuel
level
• Alwaysscrewdownfuelcap
• Cleanupanyspilledfuel
• Donotsmokewhileoperatingthegenerator
Always use caution!
Starting the generator
Fig. 1 + 3 + 4
1. Turn on fuel tap (8).
2. Turn on engine switch (5).
3. Move choke lever (6) to closed position
(to restart a warm engine, leave the choke
lever in open or half-open position).
4. Pull slowly on the starter cord until it
engages, then pull sharply to start the
engine (7).
5. Allow the engine to run until it warms up,
and then move the choke lever to the open
position (6).
Using the AC Output (230 V)
• Startthegenerator.
• Plugintheelectricalapplianceplug.
Stopping the generator
Fig. 1 + 4
1. Unplug all cords (5)
2. Turn engine switch to “OFF” (5)
3. Turn off fuel tap (8)
4. SERVICE & MAINTENANCE
PERIODIC MAINTENANCE
Daily (pre-operation check)
• Checkfuelhoseforcracksorother
damage. Replace if necessary.
• Checkexhaust-systemforleakage.
Retighten or replace gasket if necessary.
• Checkchokeoperation.
• Checkrecoilstarteroperation.
3 Months or 50 hrs
• Checkconditionofsparkplug.Adjustgap
and clean. Replace if necessary.
6 Months or 100 hrs
• Cleanfueltapandfueltankfilter.Replaceif
necessary.
• Checkfittingsandfasteners.Replaceif
necessary.
12 Months or 300 hrs
• Contactaspecializedservicecentreto
check the valve clearance.
• Checkthefanofthecoolingsystemfor
damage.
Spark plug inspection
Fig. 2
• Disconnectthesparkplugcap,andremove
any dirt from around the spark plug area.
• Removesparkplug(10)withtheplug
spanner supplied.
• Inspectthesparkplug.Itshouldbeatan
colour.
• Measurethegap(distancecontactpoint)
with a suitable gauge. The gap should be
0,7 - 0,8 mm. Correct the gap, if necessary,
by carefully bending the side electrode.
• Replacethesparkplugiftheelectrodes
are worn, or if the insulator is cracked or
chipped.
• Installthesparkplugcarefully,byhand,to
avoid cross-threading.
• Placethesparkplugwithcorrecttorque:20
Nm.
• Attachthesparkplugcap.
Exhaust screen
• Waitforexhausttocool.
• Exhaustscreenmaybeblockedupwith
carbon deposits.
• Undothescrewcapandremovethe
exhaust screen.
• Cleanthescreenwithawirebrushandrefit.
• Replaceexhaustscreenifdamaged.
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ferm PGM1007 - FGG-900 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ferm PGM1007 - FGG-900 in the language / languages: English, German, Dutch, Danish, French, Italian, Portuguese, Swedish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 5,32 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info