510120
8
Zoom out
Zoom in
Previous page
1/72
Next page
EN
8 Ferm
fluids are present.
25. Never leave the machine unattended without
first disconnecting it from the mains voltage.
26. If you hear abnormal noises, try to trace them
or take the machine to a recognized fitter, or
repair company.
27. If a part is broken or damaged, replace it or
repair it immediately.
28. Never stand in the track of the saw blade but
stand to the left or the right of the saw bench.
29. Your hands must likewise be placed next to
the track of the saw blade.
30. Always use the feedstick to push the wood
through the saw.
31. Always place the wood at the front of the saw
bench and then push it further back.
32. For mitring only the adjustable guide must be
used and the fence must be removed.
33. Never use the fence as a linear measure for
cutting off beams.
34. If the saw blade is locked: first switch off the
machine before you attend to the fault.
35. Avoid workpieces hitting back in your direction
by taking the following measures:
• Always use sharp saw blades.
• Do not saw too small workpieces.
• Never release the workpiece before it has
been completely pushed through the saw.
• Always adjust the guide parallel to the saw
blade.
• Never remove the saw protection.
36. Before you continue sawing, ensure that you
are standing firmly and that your hands are in
the required position.
37. Never use thinners to clean the machine. Only
use a damp cloth for cleaning.
38. Do not use saw blades which are damaged or
deformed.
39. Replace table insert when worn.
40. Use only saw blades recommended by the
manufacturer.
41. Take care that the selection of the saw blade
depends on the material to be cut.
42. Connect circular saws to a dust-collecting
device when sawing.
43. Use and correct adjustment of the riving knife
44. Use and correct adjustment of the upper saw
blade quard.
45 The dust that is emitted when sawing certain
types of wood can be toxic, i.s. oak, birch, ash,
beech and fibreboard. Certain dust, from
tropical wood types such as rosewood, coco
bolo and afzelia, cause cancer when breathed
in regularly. Ensure therefore that you have
good dust suction installed with a device that
fulfils the following requirements:
• Tube must fit perfectly on the connection
element
• Suction volume must be larger than 550 m3
per hour
• Vacuum at connection more than 740 Pa
• Air speed at connection more than 20 meters/
second
Ensure that the least possible wood dust is
released in the atmosphere. WIPE wood dust
away (do not blow away with pressured air),
repair leaks in the tubes and ensure
appropriate ventilation.
Do not use saw blades which are damaged or
deformed.
Always clamp or press the workpiece firmly
against the saw guide, before you carry out
the process.
Do not modify the machine; unauthorised
parts have not been tested and approved.
Mainly use:
• No unauthorised saw blades
• No unauthorised safety systems 7
• Always use the supplied safety systems!
• Always use a cavity blade for scalloping.
46. Wear ear protectors. The following facors can
be of influence in producing noise
• The kind of material to be cut
• The sawblade
• The force of which the workpiece is fed
Loud noise can lead to hearing damage.
Ensure that you wear ear protectors.
Ensure that the cavity blade is not bent,
this can also cause noise.
47 Residual risks
The following risks are inherent to the use of
these machines:
• Injuries caused by touching the rotating parts
• Injuries caused by disruption of the cutting
blade
• These risks are most evident:
• Within the range of operation
• Within the range of the rotating machine parts
In spite of the application of the relevant
safetyregulations and the implementation of
safety devices, certain residual risks cannot
be avoided. These are:
• Impairment of hearing.
• Risk of accidents caused by the uncovered
parts of the rotating cutting blade.
• Risk of injury when changing the blade.
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ferm MSM1034 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ferm MSM1034 in the language / languages: English, German, Dutch, French, Polish, Spanish as an attachment in your email.

The manual is 3,81 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info