MAINTENANCE
Make sure that the machine is not live when
carrying out maintenance work on the motor.
The Ferm machines have been designed to operate over
a long period of time with a minimum of maintenance.
Continuous satisfactory operation depends upon pro-
per machine care and regular cleaning.
REPLACING CARBON BRUSHES
•To check or replace the carbon brush loosen the cap
with a screwdriver.
•Remove the carbon brush and replace if necessary.
•Tighten the carbon brush cap.
•Change both carbon brushes simultaneously.
•Check regularly for wear and tear.
•Always change well worn carbon brushes.
•Always keep carbon brushes clean and free of hin-
drance.
DEFECTS
The machine should be checked regularly for any of the
following obvious defects and repairs carried out as
necessary.
•Cable damage
•Switch malfunction
•Short circuits
•Damage to moving parts
Cleaning
The machine housing and drill bit chuck should be clea-
ned regularly, preferably after each use.The ventilation
slots should be kept free from dust and dirt.
If the dirt does not come off use a soft cloth moistened
with soapy water.Never use solvents such as petrol,alco-
hol,ammonia water,etc.These solvents may damage the
plastic parts.
Lubrication
Have your local Ferm dealer top up the lubrication gre-
ase.
Faults
Should a fault occur,e.g.after wear of a part,please con-
tact your local Ferm dealer.
In the back of this manual you find an exploded view sho-
wing the parts that can be ordered.
ENVIRONMENT
In order to prevent the machine from damage during
transport,it is delivered in a sturdy packaging.Most of the
packaging materials can be recycled.Take these materials
to the appropriate recycling locations.
Take your unwanted machines to your local Ferm-dealer.
Here they will be disposed of in an environmentally safe
way.
GUARANTEE
The guarantee conditions can be found on the separately
enclosed guarantee card.
We declare under our sole responsibility that this
product is in conformity with the following
standards or standardized documents
EN50144-1,EN50144-2-6
EN50144-2-6
EN50155-2-6,
EN55014-1,EN55014-2,
EN61000-3-2,EN61000-3-3
in accordance with the regulations.
98/37EEC,
73/23/EEC,
89/336EEC
from 01-06-2002
GENEMUIDEN NL
W. Kamphof
Quality department
CE
ı
DECLARATION OF CONFORMITY (UK)
Ferm 548 Ferm