697750
7
Zoom out
Zoom in
Previous page
1/72
Next page
7
EN
4. OPERATION
Use of hearing protection is
recommended while operating the
circular saw.
Switching On/Off
Press knob (16) with your right-hand thumb
and keep it depressed.
Press knob (2) to start the saw.
Release knob (2) to stop the saw.
Operation
Hold the work using clamps or a vice to have
both hands free to operate the saw.
Switch on the saw and place the bottom plate
on the work.
Slowly move the saw towards the previously
drawn cutting line and slowly press the tool
forward.
Firmly press the bottom plate on the work,
otherwise the circular saw may start to vibrate,
causing the blade to break more easily.
Let the saw do the job. Do not put undue
pressure on the circular saw.
5. MAINTENANCE
Make sure that the machine is not live
when carrying out maintenance work on
the motor.
The machines have been designed to operate over a
long period of time with a minimum of maintenance.
Continuous satisfactory operation depends upon
proper machine care and regular cleaning.
Troubleshooting
Below we have listed a few probable causes and
solutions to which you can refer if your circular
saw does not function properly.
1. The temperature of the electric motor ex-
ceeds 70°C.
The motor has been overloaded by working it
too hard.
Cut more slowly and allow the motor to
cool down.
The motor is defective.
Please contact the service address on the
warranty card.
2. The tool does not work when switched on.
Damaged cord and/or plug.
Check cord and/or plug.
Defective switch.
Please contact the service address on the
warranty card.
3. When cutting it is very difficult to move the
work forward in a straight line and the cut is
not clean.
The blade is bent or blunt.
Replace the blade.
4. The circular saw makes a lot of noise and/
or does not run smoothly.
The carbon brushes are worn.
Please contact the service address on the
warranty card.
Cleaning
Keep the ventilation slots of the machine clean to
prevent overheating of the engine.
Regularly clean the machine housing with a
soft cloth, preferably after each use. Keep the
ventilation slots free from dust and dirt.
If the dirt does not come off use a soft cloth
moistened with soapy water. Never use solvents
such as petrol, alcohol, ammonia water, etc.
These solvents may damage the plastic parts.
Replacing hte carbon brushes
Remove the screws (17).
Withdraw the carbon brushes (18) from the
circular handsaw and inspect them for wear.
Place the carbon brushes back in the brush
holders provided.
Check that the copper contact on the carbon
brushes makes good contact with the copper
part in the brush holder.
Replace the screws (17) and tighten them
firmly.
If the brushes have worn down to less
than 4 mm, replace.
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ferm CSM1041P at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ferm CSM1041P in the language / languages: English, German, Dutch, Danish, French, Italian, Portuguese, Swedish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 5,28 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info