632692
8
Zoom out
Zoom in
Previous page
1/64
Next page
8
EN
4. MAINTENANCE
Make sure that the plug is removed from
the mains when carrying out
maintenance work on the motor.
The machine has been designed to operate
over a long period of time with a minimum of
maintenance. Continuous satisfactory operation
depends upon proper machine care and regular
cleaning. Before interfering in any way whatsoever
withthecompressor,pleasemakesurethat:
• Theswitchbuttonisinthe“0”positionandthe
power plug is removed from the power socket
• Theairtankisfullydecompressed(both
pressure gauges must be pointed at 0 Bar)
Malfunction
Shouldthemachinefailtofunctioncorrectly,a
number of possible causes and the appropriate
solutionsaregivenbelow:
Air loss
• Maybecausedbyapoorsealofaconnection.
• Checkallairconnectionsbywettingthem
with a soapy water solution ( Never use the
solution nearby electric connections )
• Whenthetankisemptyandbeingfilled.
The user might hear a sisseling sound by
the pressure switch. This is normal and
will stop before the compressor reach a
pressure of 1.5 bar
• Checkifthedrainvalve(14)isclosedwell
The compressor will not start
• Ifthecompressorisdifficulttostart,check:
• whetherthevoltageofthemainscorre-
sponds to that on the specification plate
(fig. 10)
• whetherelectricalextensioncablesare
being used with a faulty core or length.
• whethertheoperatingenvironmentistoo
cold(below0°C).
• whetherthereiselectricitysupply(plug
properly connected, magneto-thermal
fuses not broken).
The compressor does not shut off
Ifthecompressordoesnotshutoffwhenthe
maximumpressurehasbeenreached,thesafety
valveofthetankwillbeactivated.Itisnecessary
to contact the nearest authorised Support Service
for the repair.
Repairs and servicing should only be
carried out by a qualified technician or
service firm.
Cleaning
Regularly clean the machine housing with a
softcloth,preferablyaftereachuse.Keepthe
ventilation slots free from dust and dirt.
Ifthedirtdoesnotcomeoffuseasoftcloth
moistened with soapy water. Never use solvents
suchaspetrol,alcohol,ammoniawater,etc.
These solvents may damage the plastic parts.
Drain the tank
Compressing air will cause water in the tank.
Regularly drain the water from the tank to prevent
tankcorrosion(fig16):
• Firstreducethepressureinthetanktill
aprroxially 2 bar by connecting and activating
an air tool .
• Thenslowlyturnthedrainvalve(14)onthe
lower side of the tank open.
• Thewaterinthetankwillnowleakoutofthe
tank
Take care when compressed air is in the tank
because the water can come out with some force.
Recommended pressure max. 1-2 Bar.
Clean the air filter
Itisrecommendedtodisassemblethesuction
filter every 50 operating hours and to clean the
filter element by blowing it with compressed air
(fig.15).Itisrecommendedthatthefilterelement
is replaced at least once a year if the compressor
is working in a clean environment; more often
if the environment in which the compressor is
situated is dusty.
Replacing/topping up oil
The compressor has been supplied with synthetic
oil“SAE10W30”.Itisrecommendtofully
replace the oil of the pump system within the first
100 operating hours.
• Unscrewthedrainplug(gauge)(13)onthe
sumplid,letalltheoilrunoutandscrewback
the plug (fig. 17).
• Filltheoilviatheupperholeofthesumplid
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ferm CRM1044 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ferm CRM1044 in the language / languages: English, German, Dutch, French, Polish as an attachment in your email.

The manual is 6,79 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info