632693
8
Zoom out
Zoom in
Previous page
1/36
Next page
EN
8 Ferm
Malfunction
Should the machine fail to function correctly, a
number of possible causes and the appropriate
solutions are given below:
Air loss
• May be caused by a poor seal of a connection.
• Check all air connections by wetting them
with a soapy water solution ( Never use the
solution nearby electric connections )
• When the tank is empty and being filled.
The user might hear a sisseling sound by
the pressure switch. This is normal and will
stop before the compressor reach a
pressure of 1.5 bar
• Check if the drain valve (11) is closed well
The compressor will not start
• If the compressor is difficult to start, check:
• whether the voltage of the mains
corresponds to that on the specification
plate (fig. 10)
• whether electrical extension cables are
being used with a faulty core or length.
• whether the operating environment is too
cold (below 0°C).
• whether there is electricity supply (plug
properly connected, magneto-thermal fuses
not broken).
The compressor does not shut off
If the compressor does not shut off when the
maximum pressure has been reached, the safety
valve of the tank will be activated. It is necessary
to contact the nearest authorised Support Service
for the repair.
Repairs and servicing should only be
carried out by a qualified technician or
service firm.
Cleaning
Regularly clean the machine housing with a soft
cloth, preferably after each use. Keep the
ventilation slots free from dust and dirt.
If the dirt does not come off use a soft cloth
moistened with soapy water. Never use solvents
such as petrol, alcohol, ammonia water, etc.
These solvents may damage the plastic parts.
Drain the tank
Compressing air will cause water in the tank.
Regularly drain the water from the tank to prevent
tank corrosion (fig 16):
• First reduce the pressure in the tank till
aprroxially 2 bar by connecting and activating
an air tool .
• Then slowly turn the drain valve (11) on the
lower side of the tank open.
• The water in the tank will now leak out of the
tank
Take care when compressed air is in the tank
because the water can come out with some force.
Recommended pressure max. 1-2 Bar.
Clean the air filter
It is recommended to disassemble the suction filter
every 50 operating hours and to clean the filter
element by blowing it with compressed air (fig. 15).
It is recommended that the filter element is
replaced at least once a year if the compressor is
working in a clean environment; more often if the
environment in which the compressor is situated is
dusty.
Lubrication
It is recommended to disassemble the suction filter
every 50 operating hours and to clean the filter
element by blowing it with compressed air (fig. 15).
It is recommended that the filter element is
replaced at least once a year if the compressor is
working in a clean environment; more often if the
environment in which the compressor is situated is
dusty. The compressor makes condensed water
which collects in the tank.
It is necessary to remove the condensed water in
the tank at least once a week by opening the drain
cock (fig. 16) under the tank. Take care when
compressed air is in the bottle because the water
can come out with some force. Recommended
pressure max. 1-2 Bar.
Faults
Should a fault occur, e.g. after wear of a part,
please contact the service address on the
warranty card. In the back of this manual you find
an exploded view showing the parts that can be
ordered.
Environment
To prevent damage during transport, the appliance
is delivered in a solid packaging which consists
largely of reusable material.
Therefore please make use of options for recycling
the packaging.
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ferm CRM1042 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ferm CRM1042 in the language / languages: English, German, Dutch, French, Spanish as an attachment in your email.

The manual is 4,39 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info