compressor will not move when in operation. If the
surface area is a board or a shelf of a bookcase,
just make sure that they cannot fall down by
securing them properly. For proper ventilation and
effective cooling, it is important that the
compressor is positioned at least 100 cm from the
wall (fig. 4).
Make sure that the compressor is
transported in the right way, do not turn it
upside down and don’t lift it with hooks or
ropes (fig. 5-6).
Installing the air filter.
Remove the transport lids and replace them with
the supplied air filter before using the compressor
Starting up
• Check whether the mains voltage corresponds
to that indicated on the electrical specification
plate (fig. 10), the permitted tolerance range
should be within 5%.
• Press the switch (3) situated on the upper part
into the “0” position according to the pressure
regulator type fitted on the device (fig. 11).
• Put the plug in the plug socket (fig. 9) and start
the compressor up by putting the switch of the
pressure regulator in the “I” position. The
operation of the compressor is fully automatic.
The pressure regulator will stop the
compressor when the maximum value has
been reached and start it up when the
pressure drops below the minimum value.
Normally the difference in pressure is approx.
2 Bar/29 psi between the maximum and the
minimum value. For instance - The
compressor will stop when it reaches 8 Bar
(116 psi) (this is the maximum operating
pressure) and will start up automatically when
the pressure within the tank has dropped to 6
Bar (87 psi).
The head/cylinder/transmission pipe
assembly may reach high temperatures,
so take care when working close to these
parts and do not touch them to avoid
burns (fig. 12 - 13).
Adjusting the operating pressure
Fig. 14
It is not necessary continuously to use the
maximum operating pressure, the compressed-air
tools often require less pressure. With regard to
compressors supplied with a pressure reduction
valve it is necessary to set the operating pressure
properly.
It is possible to set the operating pressure by using
the turning knob on the reduction valve.
• By turning clockwise, the pressure will be
increased.
• By turning anti-clockwise, the pressure will be
reduced.
The compressor has two pressure gauges and
two points to connect an air hose:
• Pressure gauge on the left (9): pressure on left
outlet (7). The pressure of left this outlet can
be regulated with help of the reduction valve
(5).
• Pressure gauge on the right (8): tank pressure
+ pressure on right outlet (6)
Hints for accurate adjustment of the pressure
regulation:
• Turn the turning knob (5) anti-clockwise till
pressure is fully released
• -Connect the air tool you want to use to the
left quick coupler (6)
• Activate the air too shortly, so the pressure
gauge (7) will show the right pressure level
• Turn the turning knob (5) clockwise, till the
pressure gauge (7) shows the pressure level
you need
• Your air tool is now ready to use.
Note: when not connecting an air tool while
adjusting the pressure, it might occure the
pressure gauge (7) is not reacting accurately on
the pressure drop
4. Maintenance
Make sure that the power plug is removed
from the mains when carrying out
maintenance work on the motor.
The machine has been designed to operate over a
long period of time with a minimum of
maintenance. Continuous satisfactory operation
depends upon proper machine care and regular
cleaning. Before interfering in any way whatsoever
with the compressor, please make sure that:
• The switch button (3) is in the “0” position and
the power plug is removed from the power
socket
• The air tank is fully decompressed (both
pressure gauges must be pointed at 0 Bar)
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ferm CRM1042 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ferm CRM1042 in the language / languages: English, German, Dutch, French, Spanish as an attachment in your email.

The manual is 4,39 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info