Check that the tank is fully decompressed before connections with the tank are
unscrewed.
It is prohibited to make holes in, or welds to, or purposely to distort the compressed air tank.
Do not perform any actions on the compressor without first having taken the plug out of the
plug socket.
Do not aim water jets or jets of flammable liquids at the compressor.
Do not place flammable objects near the compressor.
Switch the pressure regulator to the "0" position (OFF = uit) during dwell time.
Never aim the air jet at persons or animals (fig. 20).
Do not transport the compressor with the tank pressurised.
N.B.: some parts of the compressor such as the head and the feed-through pipes may
reach high temperatures. Do not touch these parts to avoid burns (fig. 12-13).
Transport the compressor by lifting it or by using the special grips or handles (fig. 5-6).
Children and animals should be kept far away from the area of operation of the machine.
If you use the compressor to spray paint:
a) Do not work in enclosed spaces or near naked flames.
b) Make sure that the environment in which you will be working has dedicated ventilation.
c) Protect your nose and mouth with a dedicated mask (fig. 21).
Do not use the compressor when the electrical cable or the plug is damaged, and instruct
an authorised Support Service to replace them with an original part.
When the compressor is placed on a surface higher than the floor, it should be secured to
prevent it from falling down during operation.
Do not put objects or your hands in the protective covers to avoid physical damage and
damage to the compressor.
Do not use the compressor as a blunt instrument against persons, objects or animals in
order to prevent serious damage.
If the compressor is no longer in use, always take the plug out of the plug socket.
Always make sure that compressed-air hoses are used for compressed air and which are
characterised by a maximum pressure adjusted to that of the compressor. Do not try to
repair the hose if it is damaged.
Electrical safety
Earthing regulations
This compressor has to be earthed while in use in order to protect the operator against electrical
shocks. The compressor is provided with a two-core cable plus an earth. The electrical
connection has to be made by a qualified technician. We recommend never disassembling the
compressor and neither making any other connections into the pressure regulator. Repairs
should be carried out by authorised Support Services or by other qualified centres.
Never forget that the earthing core is the green or the yellow/green wire. Never
connect this green wire to a terminal under load.
Before replacing the plug of the feed, make sure that the earth cable is connected. If in doubt,
please call in a qualified electrician and have the earthing checked.
GB
D
NL
F
E
P
I
S
FIN
N
DK
94
Ferm
CE
KONFORMITETSERKLÆRING (DK)
Vi erklærer at under almindeligt ansvar, at dette produkt er i overenstemmelse med følgende
normer eller normative dokumenter:
EN1012-1, EN55014-1, ISO5388, EN55014-2, EN61000-3-2, EN61000-3-3
ioverensstemmelse med direktiverne:
98/37/EC, 73/23/EEC, 89/336/EEC, 87/404/EEC, 2000/14/EC, 2002/95/EC, 2002/96/EC
Målt lydtrykniveau; Lwa = 93.3 dB(A)
Garanteret lydtrykniveau; Lwa = 93 dB(A)
2000/14/EC: Det garanterede lydtrykniveau er lavere end 96 dB(A). Procedure for
overholdelsesvurdering ifølge Anneks VI.
Bemyndiget organ: TUV product service GmbH
Bemyndiget organs identifikationsnummer: 70.403.06.078.13
fran 01-08-2006
ZWOLLE NL
J.A. Bakker - van Ingen J. Lodewijk
CEO Ferm BV Quality Manager Ferm Global
Det er vores hensigt til stadighed at forbedre vores produkter, og vi forbeholder os derfor til
enhver tid retten til at ændre produktspecifikationerne uden forudgående varsel.
Ferm BV • Lingenstraat 6 • 8028 PM Zwolle • Holland
GB
D
NL
F
E
P
I
S
FIN
N
DK
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ferm CRM1030 FCO-2050 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ferm CRM1030 FCO-2050 in the language / languages: English, German, Dutch, Danish, French, Italian, Portuguese, Swedish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 1,22 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info