used in temperatures below 0°C, use API CC SAE 20 oil.
Every month:
Clean the air filter.
Every 1,000 working hours:
Refresh the oil
Carefully clean the outside of both the compressor
and the engine, to ensure an efficient cooling.
Condensation :
Regularly, i.e. several times a week, drain condensa-
tion from the air chamber, using the drain cock situa-
ted on the underneath of the air chamber.
Have your tool repaired by an expert!
This electric appliance is in accordance with the rele-
vant safety rules. Repairing of electric appliances may
be carried out only by experts other wise it may cause
considerable danger for the user.
We declare under our sole responsability that this
product is in conformity with the following
standards or standardized documents
prEN1012-1, EN60204-1, EN292, ISO5388
EN550014, EN55104, EN61000-3-2, EN61000-3-3
in accordance with the regulations:
89/392/EEC - 91/368/EEC
93/44/EEC - 93/68/EEC
73/23EEC - 89/336/EEC - 92/31/EEC
from 01-04-1999
GENEMUIDEN NL
G.M. Ensing
Quality department
Produkt: Ferm Kompressor
Typ FC-710, Art.nr. 231710
Ferm, Genemuiden, die Niederlände
1. TECHNISCHE DATEN
Es handelt sich hierbei um ein direkt gekoppelter 1-Zylin-
der Kompressor in mobiler Ausführung. Diese Kom-
pressor ist außerdem mit einem Druckreduzierventil, ei-
nem automatischen Ausschalter und einer Schnellkup-
plung ausgestattet.
Schalldruckpegel 83,8 dB(A)
LESEN SIE DIESE GEBRAUCHSANWEI-
SUNG GUT DURCH, BEVOR SIE DEN KOM-
PRESSOR BENUTZEN.
2. SPEZIELLE
SICHERHEITSVORSCHRIFTEN
BEVOR INGEBRAUCHNAHME DER KOM-
PRESSOR:
1. Stellen Sie den Kompressor in einem gut gelüf-
teten, frostfreien Raum.
Für eine optimale Ventilation und Kühlung muß der
Abstand zwischen Schutzkappe und Wand min-
destens 50 bis 60 cm betragen.
2. Kontrollieren Sie folgendes:
- stimmt die Anschlußspannung des Motors und
eventuell der Motorsicherung mit der Netzspan-
nung überein (Maschinen für eine Netzspannung
von 230 V können problemlos an eine Netzspan-
nung von 220 V angeschlossen werden);
- benutzen Sie einen geerdeten Netzanschluß.
- sind Netzkabel und Netzstecker in gutem Zu-
stand: stabil und ohne Knicke oder Beschädigun-
gen;
- Vermeiden Sie zu lange Verlängerungskabel.
- um Schäden an den Membranen zu vermeiden,
darf das Druckreduzierventil nicht völlig geschlos-
sen sein;
- Der Ölstand mittels der Ölstandmesser. Das Öl
soll zwischen den beiden Markierungen auf dem
Ölstandsmesser stehen, wenn der Kompressor
horizontal aufgestellt ist.
- vor Inbetriebnahme müssen der Luftverschluß ge-
schlossen und der Lufttank leer sein.
WICHTIG: Um zu vermeiden, daß Spannungssch-
wankungen Schaden an der Motorwicklung verursa-
chen, ist es empfehlenswert, einen Motorsicherungs-
schalter anzubringen.
Deutsch
D
CE
ı
DECLARATION OF CONFORMITY
(
UK
)
18 Ferm
AVAILABLE SPARE PARTS FOR FC-710
REF.NR. DESCRIPTION FERM NR.
1 AUTOMATIC ON/OFF SWITCH 240018
2 PRESSURE GAUGE REAR 240100
3 PRESSURE REDUCER MICRO 205887
4 NO RETURN VALVE 1/2” M 205889
5 SAFETY VALVE 1/4” 8,5 BAR 205915
7 RILSAN TUBE 4/6 205902
8 WHEEL 125 MM 205896
9 DRAIN TAP 1/4” 205888
10 RUBBER SUPPORT H50X30 208114
13 CONNECTOR 0° 208219
14 AIR PRESS TUBE 208220
Exploded
view 1
FC-710
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ferm CRM1005 FC-710 - 231710 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ferm CRM1005 FC-710 - 231710 in the language / languages: English, German, Dutch, Danish, French, Swedish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 0,52 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info