538611
5
Zoom out
Zoom in
Previous page
1/20
Next page
36 Ferm
MAINTENANCE
The mains plug always needs to be taken out of the
socket (the mains socket) during maintenance,
inspection or cleaning activities.
PERIODIC MAINTENANCE OF THE COMPRES-
SOR WILL PREVENT UNNECESSARY PROBLEMS!
FAULTS
Should a fault occur, e.g. after wear of a part, please con-
tact your local Ferm dealer.
In the back of this manual you find an exploded view
showing the parts that can be ordered.
POSSIBLE PROBLEMS AND REMEDIES
Fig. F
Air leaks through the pressure switch (1) when
the compressor is stopped
Non return valve worn or dirty not working properly
Dismantle the non return valve head clean rubber
disc (R) and/or replace it
Reassemble with care.
Reduction in performance, starting too often or
low pressure
If the demand on the air supply remains the same, check
for air leaks on pipe and hoses, the conditions of the
intake filter or belt-driven regulation.
Replace the seals of the fittings-clean or change air
intake cartridge.
Recheck the regulation of belts
The motor or the pump overheats
Not enough cooling air on the motor or the pump.
Check ambient temperature, oil level and quality,
intake filter, proper voltage.
The compressor stops after trying to start or
stops and will not start again
The air tank is full. Improper voltage or lubrication
Bad connection
Check all parameter as before.
If the problem is not resolved contact the specialist
service organisation
Anomal presence of oil in the compressed air.
Excessive oil level.
Wear of piston rings
Check oil level
Ask for Assistance
CONDENSATION
Humidity of the air wich condenses in the tank must be
drained, at least weekly through tap (6). If there is no oil
in the condensed water than it may be drained without
fear and pollution.
DRIVE BELTS TENSION
Drive belts require a precise tensioning of the belt
because at low values there are slippings on the pulley
causing overheating, and rapid wear of the belt. High
values cause excessive load on the bearing causing fast
wear of the same and motor over heating. The correct
tension value is obtained pushing with a screwdriver on
the intermediate area and you obtain a deflection of 1 cm.
OILLEVEL
The compressor comes with a special test oil, that must
be Replaced after about 100 hours of use. Check the oil
level from time to time, using the oil gauge.
When the compressor is level and has not been used for
some time, the oil level should be within the area indica-
ted by both marks on the gauge. The oil must be replaced
after every 300 hours of use or at least once a year. Use
compressor oil API CC SAE 40 rather than motor oil. If
the compressor is used in temperatures below 0°C, use
API CC SAE 20 oil.
EVERY MONTH
Clean the air filter
Every 300 working hours:
Refresh the oil
Carefully clean the outside of both the compressor
and the engine, to ensure an efficient cooling.
Condensation
Regularly, drain condensation from the air chamber,
using the drain cock situated on the underneath of
the air chamber.
Have your compressor repaired by an expert!
This electric appliance is in accordance with the relevant
safety rules. Repairing of electric appliances may be car-
ried out only by experts other wise it may cause conside-
rable danger for the user.
ENVIRONMENT
In order to prevent the machine from damage during
transport, it is delivered in a sturdy packaging. Most of
the packaging materials can be recycled. Take these
materials to the appropriate recycling locations.
Take your unwanted machines to your local Ferm-
dealer. Here they will be disposed of in an environmen-
tally safe way.
GUARANTEE
The guarantee conditions can be found on the separately
enclosed guarantee card.
Ferm 5
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ferm CRM1002 FC-720 - 230720 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ferm CRM1002 FC-720 - 230720 in the language / languages: English, German, Dutch, Danish, French, Swedish, Spanish, Finnish as an attachment in your email.

The manual is 1,27 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info