538611
4
Zoom out
Zoom in
Previous page
1/20
Next page
INSTALLATION
Fig. A
1. On/off switch
2. Reducing valve
3. Quick coupling
4. Manometer
5. Oil gauge
6. Draining valve
7. Air filter
8. Quick coupling
STARTUP AND USE
Fig. B & C
Assemble the wheels and components.
Check oil level on the viewer (5) and eventually fill-in
through the breather pipe. Level under the lower
edge, is dangerous for the integrity of the pump and
excess of oil will cause passing of oil in the compres-
sed air.
Start and stop actions have to be made only
through the on-off switch (1), to stop the compres-
sor at the plug can cause grave damage to the electric motor in
the next starting.
The compressor must be installated in a frost free well ventila-
ted room. Position the unit at least 50 cm from any wall or
obstruction to enable correct cooling. To ensure correct lubri-
cation position the unit on a level surface.
OPERATION
OPERATION THE COMPRESSOR
Fig. D
The mains switch (1) needs to be in “OFF” or “0”
position before the mains plug is connected to the
mains voltage.
Bij switching the switch (1) to “ON” or “1” the com-
pressor will operate.
Always keep the mains lead away from moving parts
of any linked up air-pressure equipment.
With the use of the reducing valve (2) it is possible to
adjust the air pressure by hand.
PRESSURE ADJUSTMENT
Fig. E
Air pressure switch (1) has already been set at the
test stage, do not change pressure valve (increase
of pressure is dangeraus for the motor.)
Keeping the tap (3) open the regulation knob pulling it up
first and then rotate the regulation knob (2) clockwise to
increase the pressure and anti-clockwise to reduce it,
never exceed the max. set value having verified the
requested value on the manometer (4). At the end of
operation return to 0 bar.
On the tank there is if required a direct outlet (8) for
max. pressure. The pressure of air supplied depends on
the value of the set pressure and the excessive air con-
sumption is shown by the low gauges values
4 Ferm Ferm 37
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ferm CRM1002 FC-720 - 230720 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ferm CRM1002 FC-720 - 230720 in the language / languages: English, German, Dutch, Danish, French, Swedish, Spanish, Finnish as an attachment in your email.

The manual is 1,27 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info