784930
11
Zoom out
Zoom in
Previous page
1/24
Next page
For further inquiries, please contact our Customer Service Team
Email: ahsservice@watkinsmfg.com Phone: +1 760 598 6464 8
ELECTRICAL REQUIREMENTS
ELECTRICAL
REQUIREMENT
DO NOT POWER THE SPA WITHOUT
FIRST FILLING WITH WATER!
DANGER – RISK OF ELECTRIC SHOCK
Installations that do not conform to the following
procedures and requirements may expose users
to electric shock.
Non-conforming installations will not be covered
under warranty.
The electrical wiring of this spa must meet the
requirements of your National Electric Code and
any applicable local codes. The electrical circuit
must be installed by an electrical contractor and
approved by a local building electrical inspection
authority.
1. Installations within 1.5 m (5 ft) of any metal
surfaces must ground the metal surfaces to the
spa. Use an 8 mm² solid copper wire and
attach it to the grounding lug on the control
box, located in the equipment compartment.
2. Only a licensed electrician may install power to
the spa.
3. Power supply installation must include a
suitably rated RCD as required by your
national/local electric code. The circuit breaker
must be dedicated and should not be shared
with any other appliances. It must be labeled
and easily accessible to users.
4. The electrical supply for the spa must include a
suitable circuit breaker to open all ungrounded
supply conductors to comply with your
national/local electric code. The disconnecting
means must be readily accessible to the spa’s
occupant but installed at least
1.5 m (5 ft) from the spa water.
5. Power supply lines must be hard wired
into the power pack. When hard wired, the
use of a shut-off box near the spa is also
recommended. This box provides a quick and
convenient method to shut off power to the spa
for emergencies and maintenance.
6. Supply lines must be properly sized as per
your national/local electric code. A ground line
must be provided that is as large as the largest
current carrying conductor, but no less than 8
mm². Use copper wiring only.
7. Please open the front cover of the control box,
and follow the instructions and wiring diagram
printed on the backside.
8. 230V HARD WIRED SPAS
Wire size must be appropriate per your
national electric code and/or local codes.
Wire size is determined by length of run
from breaker box to spa and maximum
current draw.
All wiring must be copper to ensure
adequate connections. Do not use
aluminum wire.
Equipment access is below the
topside control panel on most
spas
.
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fantasy Entice at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fantasy Entice in the language / languages: English as an attachment in your email.

The manual is 0.7 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info