709853
17
Zoom out
Zoom in
Previous page
1/72
Next page
ENGLISH
17
FUMES DISCHARGE (only intended for personnel qualied to assemble the hood)
EXTERNAL EXHAUST HOOD VERSION SUCTION
In this version, the kitchen fumes and vapours are conveyed outside through an exhaust pipe.
The air outlet fitting that extends from the upper part of the hood must be connected with the pipe that conducts
the fumes and vapours to an external output.
Do not connect the equipment to discharge pipes of fumes produced from combustion (for example boil-
ers, replaces, etc) and you are to comply with the regulations in force regarding external air discharge.
The fumes outlet pipe must have:
- a diameter not less than that of the hood fitting;
- a slight slope downwards (drop) in the horizontal sections to prevent any formation of condensation from flowing
back to the hood;
- the minimum required number of bends;
- minimum required length (long pipes with various bends can reduce suction performance of the hood and trigger
vibrations of the check valve).
If the fumes outlet pipe passes through cold environments such as attics, etc., it is possible that water condensation
forms due to sudden changes in temperature. In this case, you are required to insulate the pipes.
The hood supplied with an 800 m
3
/h motor is equipped with a check valve whose function is to prevent external air exchange when the hood is not
operating: refer to the instructions
C on page 5 for assembly.
When the kitchen hood is used simultaneously with other appliances that use gas or other fuels, the room must have sucient ventila-
tion, in accordance with regulations in force.
The active carbon filters in this version are to be removed. Refer to the instructions H on page 7 for removal.
Deviation for Germany: when the kitchen hood is used at the same time as appliances that are powered by energy other than electricity, the negative pressure
in the room must not exceed 4 Pa (4 x 10-5 bar).
HOOD VERSION WITH INTERNAL RECIRCULATION FILTERING
In this model, air passes through the active carbon filters to be purified and is then recycled into the kitchen envi-
ronment.
Check that the active carbon filters are assembled onto the hood, if not, install them as indicated in the in-
structions
H on page 7 .
If the hood is set up with a filtering version, the check valve must not be assembled: remove it if it is on the air outlet
fitting of the motor (carry out operations described in the instructions
C on page 5 in reverse order).
ASSEMBLY INSTRUCTIONS (only intended for personnel qualied to assemble the hood)
Phase
A page 5
Place the support bar (S) on the installation wall at a height (H) from the cooker indicated in the figure (Fig.
1
).
Use a spirit level to check the horizontal alignment and draw 2 marks at each end of the support bar, this is where the holes will be drilled (Fig.
2
-
3
).
Drill the holes, insert 2 expansion plugs (ø 8mm) and fasten the bar with the relative screws (V1) (Fig.
4
).
The xing kit (screws, plugs, and brackets) supplied with the hood can only be used on masonry walls: should it be necessary to
install the hood onto walls in a different material, assess other fixing systems keeping the wall resistance and weight of the hood in mind
(indicated on page 3).
Phase
B page 5
Hook the hood onto the support bar (Fig.
1
).
Adjust the alignment of the hood by using the fixing screws (Fig.
2
). The upper screw (B) adjusts the distance from the wall, the lower one (C)
adjusts vertical scrolling.
To prevent the hood from falling due to a pressure below, fasten it to the wall with expansion plugs and relative screws (V2) using the appropriate
holes on the back of the hood (Fig.
3
).
Phase
C and D page 5
EXTERNAL EXHAUST HOOD VERSION SUCTION
Only for versions with an 800 m
3
/h motor: if you wish, install the check valve (M) as indicated in figure C.
Connect the air outlet connection of the hood to the external discharge with a suitable pipe.
HOOD VERSION WITH INTERNAL RECIRCULATION FILTERING
Check that the active carbon filters are assembled onto the hood, if not, install them as indicated in the instructions
I on page 7.
If installed, remove the check valve assembled on the hood air outlet fitting (carry out the instructions described C on page 5 in reverse order).
Phase E page 6
Insert the extension (H) in the chimney (G) (Fig.
1
) and fasten the assembly to the body of the hood using screws (V3)(Fig.
2
).
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Falmec Onda at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Falmec Onda in the language / languages: All languages as an attachment in your email.

The manual is 14,77 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info