35
EnglishEnglish
Defects - Malfunctions
Direct action by the customer
Before calling service personnel, to avoid useless expense, check whether the machine problem corresponds to one of the
cases listed below.
Defects - Malfunctions
PROBLEM
Leaking from the filter-holder rim (10).
Coffee dispensing time too short.
Coffee drips out of machine.
Loss of water under the machine.
SOLUTION
Clean using the special brush provided.
Use a finer grind.
Use new coffee.
Clean.
Use a coarser grind.
Clean.
Clean.
CAUSE
Underpan gasket dirty with coffee.
Coffee ground too coarse.
Coffee too old.
Filter holes blocked or filter-holder (10)
outlet hole dirty.
Coffee ground too fine.
Discharge well clogged up.
Discharge pan hole blocked.
Interventions by a specializes technician
PROBLEM
Infusion time too short
Rapid dispensing.
Coffee very bland, without cream.
(Same defects on all groups).
Infusion time very short.
Rapid dispensing.
Coffee very bland, without cream.
(Same defects on all groups).
Low coffee yield.
Slow dispensing.
Coffee cold and bland.
Fast dispensing, coffee bland.
Pressure gauge pump indicates
pressure greater than 9 bar.
Low coffee yield.
Fast dispensing.
Coffee hot and bland.
Coffee cold, bland and without cream.
Normal infusion and dispensing times.
Coffee cold in the morning at start of work.
SOLUTION
This defect is associated to other
secondary symptoms which may be
caused by a number of other causes as
per the previous points. Do not adjust the
machine until all other causes have been
excluded.
The capacity of the group without filter
must be 100 cm³ in 8 ÷ 10 seconds.
If the group is operated without the filter-
holder, thin, isolated jets will be
dispensed instead of one central jet.
Coffee grounds in cup.
Move group to and fro to remove air bubble.
When touching the water tube it is warm
near to the machine.
Pressure gauge calibrated with values
that are too low.
See switching on instructions.
CAUSE
Coffee grounds too course.
Old coffee.
Group nozzle widened through use.
OR gasket in cone-shaped section
leaks.
Infusion valve remains open
Filter edge broken.
Spout dirty.
Pump out of calibration.
By-pass valve blocked.
Filters with perforations widened.
Coarse grinding.
Air bubble in thermosiphon circulation.
Check valve does not hold (with low
pressure in system).
Heat exchangers emptied.
Heat exchanger defective (shows
pressures higher than real values).
Air in boiler.
27


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Faema E61 Jubile at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Faema E61 Jubile in the language / languages: English, German, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 1,86 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info