“A” LOGIC PULSES
AUTOMATED
SYSTEM STATUS
OPEN A CLOSE STOP FSW OP FSW CL FSW CL/OP
CLOSED
opens and closes
after the pause time
no effect
no effect
(OPEN disabled)
no effect
(OPEN disabled)
no effect
no effect
(OPEN disabled)
AT OPENING
no effect (1) recloses the gate stops operation
see Advanced
Programming level
no effect
stops and when
no longer engaged
opens (stores
CLOSE)
OPEN IN PAUSE
recharges pause
time (1)
recloses the gate stops operation no effect
recharges pause
time (CLOSE
disabled)
recharges pause
time
(CLOSE disabled)
AT CLOSURE
reopens the gate no effect stops operation no effect
reverses to opening
(see 2nd lev. prog.)
stops and when
no longer engaged
opens (stores
CLOSE)
STOPPED
closes the gate closes the gate
no effect
(OPEN/CLOSE
disabled)
no effect
(OPEN disabled)
no effect
(OPEN disabled)
no effect
(OPEN/CLOSE
disabled)
“A1” LOGIC PULSES
AUTOMATED
SYSTEM STATUS
OPEN A CLOSE STOP FSW OP FSW CL FSW CL/OP
CLOSED
opens and closes
after the pause time
no effect
no effect
(OPEN disabled)
no effect
(OPEN disabled)
no effect
no effect
(OPEN disabled)
AT OPENING
no effect (1) recloses the gate stops operation see 2nd lev. prog.
continues to open
and recloses
immediately
stops and when
no longer engaged
opens (stores
CLOSE)
OPEN IN PAUSE
recharges pause
time (1)
recloses the gate stops operation no effect
stops and when
no longer engaged
closes immediately
recharges pause
time
(CLOSE disabled)
AT CLOSURE
reopens the gate no effect stops operation no effect
reverses to opening
(see 2nd lev. prog.)
stops and when
no longer engaged
opens (stores
CLOSE)
STOPPED
closes the gate closes the gate
no effect
(OPEN/CLOSE
disabled)
no effect
(OPEN disabled)
no effect
(OPEN disabled)
no effect
(OPEN/CLOSE
disabled)
Tab. 1/b
Tab. 1/a
In brackets, the effects on the other inputs when the pulse is active.
11.9 OPERATING LOGICS TABLES
A: AUTOMATIC logic (Tab. 1/a)
A1: AUTOMATIC 1 logic (Tab. 1/b)
EP: STEP-BY-STEP logic (Tab. 1/c)
E: SEMI-AUTOMATIC logic (Tab. 1/d)
PE: PHOTOCELL AUTOMATIC logic (Tab. 1/e)
C: DEAD-MAN logic (Tab. 1/f)
CU: CUSTOM logic (this logic cannot be selected; it appears
automatically each time you go to the parameter
LO and any
parameter is changed from its default setting).
“EP” LOGIC PULSES
AUTOMATED
SYSTEM STATUS
OPEN A CLOSE STOP FSW OP FSW CL FSW CL/OP
CLOSED
opens the gate no effect
no effect
(OPEN disabled)
no effect
(OPEN disabled)
no effect
no effect
(OPEN disabled)
AT OPENING
stops operation (1) recloses the gate stops operation see 2nd lev. prog. no effect
stops and when
no longer engaged
opens (OPEN stops
- CLOSE is stored)
OPEN IN PAUSE
recloses the gate (1) recloses the gate
no effect
(OPEN/CLOSE
disabled)
no effect
no effect
(CLOSE disabled)
no effect
(OPEN/CLOSE
disabled)
AT CLOSURE
stops operation no effect stops operation no effect
reverses to opening
(see 2nd lev. prog.)
stops and when
no longer engaged
opens (OPEN stops
- CLOSE is stored)
STOPPED
resumes motion
in the opposite
direction. After STOP
always closes
closes the gate
no effect
(OPEN/CLOSE
disabled)
no effect
(OPEN disabled)
no effect
(OPEN disabled)
no effect
(OPEN stops -
CLOSE is stored)
Tab. 1/c
28


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for FAAC C850 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of FAAC C850 in the language / languages: English as an attachment in your email.

The manual is 13,57 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info