560694
26
Zoom out
Zoom in
Previous page
1/40
Next page
24
C850 532015 Rev. A
ENGLISH
Fig. 45
11.8 EXPERT PROGRAMMING LEVEL
The expert programming level is used only if you wish to perform an advanced customisation of the operating logics.
Before making changes at this level, ensure that the parameters you wish to change and their effect on the
automated system are fully understood.
To access EXPERT PROGRAMMING LEVEL, press F and, holding it, press + for approximately 10 seconds. The use of F, +
and - is the same as in the other two programming levels.
EXPERT PROGRAMMING LEVEL 10 sec
Display Function Setting
01
If this function is activated, automatic closing occurs after the pause time.
Y = automatic closing
no = disabled
02
When this function is activated, 2-input operating mode is obtained: OPEN for opening and
CLOSE for closing.
Y = 2-input operation
no = disabled
03
Activation of OPEN and CLOSE input levels recognition (command held).
That is to say, the board recognises the level (e.g. if with OPEN held you press STOP; when
the latter is released, the automated system will continue to open). If 03 is disabled, the
board commands a manoeuvre only if there is an input variation.
Y = level recognition
no = recognition at status variation
04
Activation of DEAD-MAN opening (command always pressed). Releasing the OPEN
command will stop operation
Y = active
no = disabled
05
When this function is activated, the OPEN command during opening will stop movement.
If the parameter 06 is “no”, the system is ready for opening.
If the parameter 06 is “Y”, the system is ready for closing.
Y = stops when opening
no = disabled
06
When this function is activated, the OPEN command during opening will reverse movement.
If the parameters 05 are 06 are “no”, OPEN will have no effect during opening.
Y = reverses when opening
no = disabled
07
When this function is activated, the OPEN command during pause stops operation.
If the parameters 07 and 08 are “no”, OPEN resets the pause time.
Y = stops when paused
no = disabled
08
When this function is activated, the OPEN command during pause causes closing.
If the parameters 07 and 08 are “no”, OPEN resets the pause time.
Y = closes when paused
no = disabled
09
When this function is activated, the OPEN command during closing stops operation,
otherwise it reverses movement.
Y = stops
no = reverses
10
Activation of DEAD-MAN closing (command always pressed). Releasing the CLOSE
command will stop operation
Y = active
no = disabled
11
When this function is activated, the CLOSE command has priority over OPEN, otherwise
OPEN has priority over CLOSE.
Y = active
no = disabled
12
When this function is activated, the CLOSE command commands closing when released.
As long as CLOSE is activated, the unit stays in closing pre-ashing mode.
Y = closes when released
no = closes immediately
11.6 E850 BOARD START-UP
11.6.1 VERIFYING THE BOARD LEDs
Before final start-up of the E850 electronic control unit, check the
activation status of the board LEDs.
The LEDs indicate the status of the board inputs and are extremely
important for movement of the automated system:
LED ON
: contact CLOSED
LED OFF : contact OPEN
Figure 45 shows the standard LED
configuration with the automated
system CLOSED and ready to open.
The FSW OP (DL5), STOP (DL4), FSW
CL (DL3) and FCO FCC (DL8) inputs
are safety inputs with N.C. (normally
closed) contact, therefore the corre-
sponding LEDs are ON.
The FCA and FCC LEDs are the N.C. contacts of the limit switches
which, if engaged, will open thus turning off the corresponding
LED:
With the Automated
System CLOSED
FCC ENGAGED
With the Automated
System OPEN
FCO ENGAGED
11.6.2 VERIFYING THE BUS STATUS
Consult this paragraph if BUS photocells are installed, as
described in paragraph 11.4.3.
Enter the basic programming level and visualise the
on-screen programming parameter
bu.
This parameter must feature a horizontal centre line to
confirm that all the BUS photocell pairs are engaged
and, if necessary, press + to check the devices entered,
as described in paragraph 11.5.3.
11.7 TESTING THE AUTOMATED SYSTEM
Once programming is completed, ensure that the system is
operating correctly.
Especially check that the automated system power is correctly
adjusted and that the safety devices connected to it operate
accordingly.
26


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for FAAC C850 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of FAAC C850 in the language / languages: English as an attachment in your email.

The manual is 13,57 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info