11.5.2 CHANGING THE PRE-SETTINGS
Changing the parameter dF lets you automatically load a
configuration which will modify all the programming values at
every level with pre-set values.
This option is a handy starting point to quickly program the E850
for operation.
The selectable PRE-SETTING is:
01
Loaded FAAC default
To make the pre-setting value loading effective, select
pre-setting
(
01
) and exit the basic programming level.
EXAMPLE: by selecting
01 and exiting the basic programming
level, all FAAC production values are loaded and can be found in
the BASIC, ADVANCED AND EXPERT level tables in the “Default”
column. The E850 is therefore configured to move a gate.
LOADING OF A PRE-SETTING CANCELS
ALL PREVIOUSLY MADE CHANGES TO ANY
PROGRAMMING PARAMETER. IF YOU DO NOT
WISH TO LOAD A PRE-SETTING, LEAVE THE
PARAMETER
dF ON 00.
The parameter dF, unlike the others, does not
store the selected value but always returns to
displaying
00 as a standard condition.
It is therefore not possible to recognise which pre-setting was
set previously.
If you do not wish to load a pre-setting, ALWAYS leave the
parameter
dF set on 00 and go on to the next programming
parameter.
Ensure that you perform default loading and
exit the basic programming level BEFORE
you change any other parameters to avoid
cancelling all the changes made.
11.5.3 NEW BUS E850 SIGNAL
Segment ON = means that at least one corresponding BUS device
is active/engaged.
Segment OFF = means that no corresponding BUS device is
active/engaged.
(when the gate is closed at rest).
BUS STATUS segment always on.
At the BASIC programming level there will be the parameter
bu
for BUS devices:
when F is released,
no will appear only if no BUS device
is entered.
By simultaneously pressing + and for 5 sec., a new entry will
be made. During this time, the writing
no will flash and once the
BUS entry procedure is completed,
no will become Y. When +
and are released,
Y will disappear and the BUS device status
signal will appear. With the gate closed at rest with no BUS device
active/engaged, the signal shown in Fig.39.
If once the entry is completed there are NO BUS devices, the
display will go back to
no.
When an entry is completed, to verify the
devices recognised in the basic programming
level by the BUS device status signal, press
and hold +. The display will show the types
of BUS devices entered.
Fig. 39
Fig. 39
The example shown above indicates the visualisation of at least
one of the following types of BUS accessories entered:
FSW OP, FSW CL, FSW OPEN.
Release + and press F to continue programming the other
parameters.
The BUS communication system uses a self-diagnostic function
able to provide connection error signals or BUS accessories
configuration error signals.
The display will show a FLASHING
cc, as
in figure 41, if there is a SHORT-CIRCUIT
along the BUS line. Check the connections
made (section 11.4.3)
The display will show a FLASHING
Er, as in
figure 42, in the following cases:
more than one pair of BUS photocells
have the same address.
CALLING error.
FAIL SAFE error.
In the latter case, check all the addresses set on all the installed
BUS photocells, referring to section 11.4.3.
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for FAAC C850 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of FAAC C850 in the language / languages: English as an attachment in your email.

The manual is 13,57 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info